Footprint to prediction: low-cost, three-class foot arch screening using a Harris mat.
Hariprasad Ramachandran, Srivardan Balu, Kaushik Ramakrishna Haran, Sanjay Murugan Selvi, Sharmila Nageswaran
School of Electronics Engineering, Vellore Institute of Technology, Vellore, Tamil Nadu, India.
Key points
From the paper's conclusion- The research work described herein advances a computer-assisted automated classification of the foot arch from footprint images obtained on the Harris mat and transformed into contact-area visualizations through image processing, then classified using machine learning approaches, including a Convolutional Neural Network (CNN)-based model with MobileNetV2 and a Support Vector Machine (SVM) baseline
Abstract
Arch type foot pathologies of Pes Cavus (high arch), Pes Planus (flatfoot), and Normal Arch patterns are good predictors of foot health that affect gait, posture, and predispose to musculoskeletal disorders. The research work described herein advances a computer-assisted automated classification of the foot arch from footprint images obtained on the Harris mat and transformed into contact-area visualizations through image processing, then classified using machine learning approaches, including a Convolutional Neural Network (CNN)-based model with MobileNetV2 and a Support Vector Machine (SVM) baseline for comparison. The system's performance was validated on a dataset of 106 footprint impressions collected from 53 healthy young university students. The training set was subsequently augmented to 300 images, while evaluation was performed on 22 held-out original (non-augmented) images. The total accuracy for the CNN model was 77.3%, with an F1-score by class of 0.78 for Pes Cavus, 0.92 for Pes Planus, and 0.62 for Normal Arch. Precision values were 0.70 (Pes Cavus), 0.86 (Pes Planus), and 0.80 (Normal Arch), and recall values were 0.88, 1.00, and 0.50, respectively. The SVM model had an accuracy of 54.6%. Cohen's Kappa of 0.658 indicated substantial agreement between model predictions and reference labels, and ROC analysis showed promising classification performance within the evaluated dataset, with AUC estimates of 0.848 for Pes Cavus, 0.990 for Pes Planus, and 0.830 for Normal Arch.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Research on Plantar Signal Measurement and Foot Arch ClassificationElectronics · 2026
- Explainable AI-based clinical decision support system for flatfoot classification using deep learning.Frontiers in digital health · 2026
- Explainable artificial intelligence for automated flatfoot detection in foot x-ray imagesDiscover Artificial Intelligence · 2026
- Standardization of body weight distribution using a Force-Sensitive Resistor (FSR) matrix and foot analytics.PloS one · 2026
- Development and internal validation of a multimodal deep learning model for screening-level lower-limb alignment using plantar 3D foot scans.PLOS digital health · 2026
- Classifying Foot Arch Morphologies Using High-Sensitivity Pressure Mat Technology: Prevalence Estimates and Associations With Pain, Activity Limitations, and Patient Characteristics in a Community-Based Adult Sample.Cureus · 2026