Frontiers in radiologyOpen accessSegmentation

AV-MapNet: geodesic vessel tokenization and sequential refinement for retinal vessel segmentation and artery-vein classification.

Owais Ali, Di Xiao, Nasir Yasin, Jinglan Zhang, Yuefeng Li

School of Computer Science, Queensland University of Technology, Brisbane, QLD, Australia. · Telemedc Pty Ltd, Brisbane, QLD, Australia.

Key points

From the paper's conclusion
  • These results demonstrate that combining sequential refinement with vessel-conditioned geodesic representation provides an effective framework for structurally informed retinal vascular analysis.

Abstract

Accurate retinal vessel segmentation and artery-vein (A/V) classification are important for quantitative analysis of retinal vascular morphology, yet remain challenging in thin vessels, bifurcations, crossings, low-contrast regions, and pathological structures. This work proposes AV-MapNet, a structure-aware deep learning framework that integrates multi-scale vessel extraction, sequential residual refinement, Geodesic Vessel Tokenization (GVT), topology-aware token reasoning, and vessel-guided A/V classification. The retinal vascular tree is first extracted using a residual encoder-decoder with multi-scale dilated context and progressively corrected through recurrent vessel refinement. GVT then organizes intermediate features into vessel-aligned tokens according to refined vessel probability, local orientation, boundary ambiguity, and junction information using differentiable geodesic propagation. The resulting tokens undergo structure-biased long-range reasoning and are reconstructed into dense contextual features for subsequent A/V classification. Independent artery and vein branches are conditioned on the refined vessel representation and undergo class-specific sequential refinement before joint normalization. AV-MapNet achieved vessel segmentation DSC values of 83.01%, 85.21%, and 87.10% on RITE, HRF, and DRIVE, respectively, with corresponding accuracies of 97.67%, 98.01%, and 98.52%. Structural evaluation on the 20-image DRIVE test set yielded a clDice of 0.8490 ± 0.0194 , with Betti-0 and Betti-1 errors of 0.9071 ± 0.1890 and 0.2391 ± 0.1066 , respectively. For direct binary A/V classification on valid labelled vessel pixels, AV-MapNet achieved accuracies of 96.01%, 96.48%, and 97.20% on LES-AV, AV-DRIVE, and RITE, respectively. These results demonstrate that combining sequential refinement with vessel-conditioned geodesic representation provides an effective framework for structurally informed retinal vascular analysis.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers