Patient-specific proximal femoral plate combined with a modular 3D-printed osteotomy guide system in children with developmental dysplasia of the hip: a retrospective comparative study
Haoran Qi, Pengkun Wang, Lian Feng
Harbin Medical University · University of Science and Technology of China
Key points
From the paper's conclusion- Conclusions A patient-specific proximal femoral plate combined with a modular 3D-printed osteotomy guide system appears to be a feasible and safe option for proximal femoral osteotomy in children with DDH.
Abstract
Background To evaluate the clinical value of a patient-specific proximal femoral plate combined with a modular 3D-printed osteotomy guide system in children with developmental dysplasia of the hip (DDH) undergoing proximal femoral osteotomy. Materials and methods This retrospective study included children with DDH who underwent proximal femoral osteotomy assisted by a modular 3D-printed osteotomy guide system. Patients were divided into a customized plate group and a conventional locking compression pediatric hip plate (LCP-PHP) group. Perioperative outcomes, including blood loss, operative time for the femoral procedure, and fluoroscopy frequency, were compared. Radiographic parameters, including neck-shaft angle (NSA), femoral anteversion angle (FAA), acetabular index (AI), and center-edge (CE) angle, were assessed postoperatively and at final follow-up. Functional outcomes, complications, and measurement reliability were also evaluated. Results A total of 40 patients were included. The mean follow-up duration was 32.32 ± 4.18 months in the customized plate group and 31.39 ± 3.88 months in the conventional LCP-PHP group. No major complications were observed in either group. Compared with the conventional LCP-PHP group, the customized plate group showed a significantly smaller loss of planned NSA correction, whereas FAA correction loss was similar between groups. No significant between-group differences were found in blood loss, operative time, fluoroscopy frequency, postoperative radiographic parameters, final follow-up outcomes, or functional results. Reliability analysis demonstrated excellent reproducibility of radiographic measurements, supporting the validity of the difference in NSA correction loss. Conclusions A patient-specific proximal femoral plate combined with a modular 3D-printed osteotomy guide system appears to be a feasible and safe option for proximal femoral osteotomy in children with DDH. Compared with the conventional LCP-PHP, the customized plate more accurately maintained the planned NSA correction and may help improve correction accuracy in pediatric hip reconstruction.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- EP1.71 Early Outcomes of Periacetabular Osteotomy Combined with Rotational Osteotomy at the Base of the Femoral Neck for Developmental Dysplasia of the Hip with Complex Femoral Sided Deformity and Inadequate Femoroacetabular CongruenceJournal of Hip Preservation Surgery · 2026
- Digital simulation and 3D-printed guide-assisted surgical correction of a complex pediatric hip deformity: a case report and literature review.Frontiers in pediatrics · 2026
- TP4.3 Accuracy of Patient Specific Guide to Achieve Pre-Operatively Templated Correction of Hip Dysplasia with PAOJournal of Hip Preservation Surgery · 2026
- MRI-CT fusion-based digital true hip reconstruction in pediatric developmental dysplasia of the hip: a preliminary feasibility report.Frontiers in surgery · 2026
- Growth Stimulating Minimal Acetabuloplasty, Alongside Hip Open Reduction: A Simpler One-stop Operative Treatment for Developmental Dysplasia of the HipJournal of Pediatric Orthopaedics · 2026
- FP7.2 Patient-Specific Osteotomy Plane Configuration Optimises Femoral Head Coverage and Bone Overlap in Bernese Periacetabular Osteotomy for Hip Dysplasia: A Three-Dimensional Simulation StudyJournal of Hip Preservation Surgery · 2026