Beyond visual comfort: comparing pupillometry and subjective measures of cognitive strain in workplace lighting.
D-Filipa Ferreira, Ana-Carolina Fonseca, Simão Ferreira, Luís Pinto-Coelho, Matilde A Rodrigues
RISE-Health, Center for Translational Health and Medical Biotechnology Research (TBIO), ESS, Polytechnic of Porto, Porto, Portugal. · INESCTEC, Campus of the Engineering Faculty of the University of Porto, Porto, Portugal.
Key points
From the paper's conclusion- A direct comparison between illuminance conditions (Holm-corrected) revealed no significant effects of illuminance on pupillary parameters (|d| ≤ 0.19), but subjective workload increased with illuminance during the most demanding task (d = 0.81). Both pupillometry and subjective measures detected significant pairwise differences between task demand levels consistently under both illuminance conditions (Kendall's W ranging from 0.29-0.35 for pupil diameter variance to 0.34-0.58 for NASA-TLX and VAS Stress). No significant differences were found for the writing task or the 2-back task across any measure.
Abstract
INTRODUCTION: This study evaluated the discriminative sensitivity of pupillometry, relative to subjective self-report measures, as an objective indicator of cognitive load during screen-based tasks performed under two workplace illuminance levels (300 and 500 lux). Inadequate workplace illuminance is associated with visual fatigue, stress, and impaired attention, yet its effect on cognitive strain during screen-based tasks remains underexplored through objective physiological indicators, particularly given the confounding influence of the pupillary light reflex (PLR) on pupillometric measures. METHODS: Forty-eight working-age adults performed writing and working memory (N-back) tasks under both conditions in a controlled laboratory replicating office environments; pupil diameter was recorded continuously using Pupil Labs Core eye-tracking glasses, while the NASA-TLX and Visual Analog Scales (VAS) assessed subjective workload, stress, fatigue, and eye strain. RESULTS: A direct comparison between illuminance conditions (Holm-corrected) revealed no significant effects of illuminance on pupillary parameters (|d| ≤ 0.19), but subjective workload increased with illuminance during the most demanding task (d = 0.81). Both pupillometry and subjective measures detected significant pairwise differences between task demand levels consistently under both illuminance conditions (Kendall's W ranging from 0.29-0.35 for pupil diameter variance to 0.34-0.58 for NASA-TLX and VAS Stress). No significant differences were found for the writing task or the 2-back task across any measure. DISCUSSION: The results indicate that pupillometry and subjective self-report measures are comparably sensitive to task demand, while only subjective workload was sensitive to illuminance, underscoring the value of combining objective and subjective indicators in occupational lighting research.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Relationships between light exposure and aspects of cognitive function in everyday lifeCommunications Psychology · 2025
- Comparing Conventional and Non-Visual Lighting Parameters for Multidimensional Human Responses in Windowless Enclosed WorkspacesBuildings · 2026
- Pupil baseline trends on ~ 10-s timescales track near-term task performanceScientific Reports · 2026
- Cognitive workload across subjective and electrodermal measures in relation to previous-night sleep.Frontiers in cognition · 2026
- Eye-Tracking for Cognitive Load Assessments in a Manufacturing Environment: A Feasibility StudyOccupational Health · 2026
- Comparing Eye-Tracking Metrics with the Driver Activity Load IndexJournal of Eye Movement Research · 2026