Geometry-informed temperature band screening for crop microclimate management in a commercial tomato greenhouse.
Xiaojing Liu, Jianlin Li, Hongsheng Lin, Shuhui Shi
College of Sciences, Shenyang Institute of Engineering, Shenyang, China. · Horticulture Program, Dalian Art College, Dalian, China.
Key points
From the paper's conclusion- On the same observed temperature series, crop reference band membership increased from 21.02% at ±1.0 °C to 25.22% at ±1.21 °C, while the total degree-hour index decreased by 9.17%.
Abstract
Commercial greenhouses require temperature strategies that coordinate natural ventilation and screens with supplementary heating while maintaining a suitable crop environment. We evaluated a low input framework that combines a spectral geometry descriptor, one hour autoregressive prediction with exogenous inputs (ARX), temperature-conditioning degree-hour indices, vapor pressure deficit (VPD) exposure, and recorded vent, screen, and heating water data to screen temperature bands for field testing. The case study used 24,132 complete five minute interval starts from a 104 m × 68 m × 6.5 m Venlo tomato compartment operating at 1.25 plants/m2, 3.75 productive stems/m2, and an annual yield of approximately 45 kg/m2. The Rayleigh-Ritz solution gave CG = 7.188 m2, and the maximum single mode error was 4.26% across the numerical test grid. A preliminary fourth root scaling hypothesis mapped the declared reference half widths of 0.8-1.2 °C to candidate half widths of 0.97-1.45 °C; the 1.21 °C midpoint is an illustrative scenario conditional on the declared benchmark and reference half width. Alternative benchmarks produced multipliers of 1.047-1.290, confirming benchmark dependence. Within-site temporal holdout evaluation of ARX yielded RMSE 0.798 °C and R 2 = 0.911; this result evaluates temporal prediction separately from geometry scaling. On the same observed temperature series, crop reference band membership increased from 21.02% at ±1.0 °C to 25.22% at ±1.21 °C, while the total degree-hour index decreased by 9.17%. The 9.17% value is a retrospective index difference rather than a measured energy saving. Only 28.38% of daytime records were within the 0.5-1.2 kPa VPD reference interval, showing that the prevailing moisture environment remained a constraint beyond temperature-band flexibility. The framework therefore supplies candidate bands and crop-environment criteria for controlled evaluation of energy use, plant responses, yield, and fruit quality.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Longitudinally and Vertically Balanced Sparse Indoor Temperature-Humidity Sensing Preserves Threshold-Defined Risk Inference in a Chinese Solar Greenhouse.Sensors (Basel, Switzerland) · 2026
- Multi-Step Stability Selects Sparse Surrogate Models for Economic Greenhouse Climate Control: An in Silico Study of Feature-Library Design and Actuator-Pathway SurvivalProcesses · 2026
- Prediction of greenhouse temperature and humidity across growing seasons: Hybridization of process-based model and deep neural networksInformation Processing in Agriculture · 2025
- Environmental Parameter Prediction and Variable-Frequency Data Acquisition Strategy Optimization for Greenhouses Based on LSTMAgriculture · 2026
- A Composite‐Kernel Mixture of Experts GPR Framework With Bayesian Hyperparameter Optimization for Accurate Mass Prediction in Greenhouse Solar DryerJournal of Food Process Engineering · 2026
- Intelligent Greenhouse Temperature Management: A Closed-Loop Perspective on Sensing, Modeling, Control, and DeploymentAgriculture · 2026