Determination of swimming training intensity zones using different physiological testing methods: a systematic review.
Susana Iturralde-Stokman, Daniel Juárez Santos-García, Francisco Hermosilla-Perona
AExPH, Facultad de Ciencias Biomédicas y de la Salud, Universidad Alfonso X el Sabio (UAX), Villanueva de la Cañada, Madrid, Spain. · Sport Training Laboratory, University of Castilla-La Mancha, Toledo, Spain.
Key points
From the paper's conclusion- Objective: The aim of the study was to analyse the scientific evidence about the determination of training zones in swimming, comparing the different physiological methods and variables used to define them.
Abstract
UNLABELLED: Introduction: The prescription of training intensity in swimming based on different intensity zones defined by physiological thresholds constitutes a key factor in training adaptations. However, the wide variety of tests used to estimate these parameters hinders the establishment of a consensus. OBJECTIVE: The aim of the study was to analyse the scientific evidence about the determination of training zones in swimming, comparing the different physiological methods and variables used to define them. METHODS: To this end, a systematic review was conducted following the PRISMA guidelines. Three databases were analysed, and the PEDro and AXIS scales were applied for quasi - experimental and observational studies respectively. A total of 5629 articles were identified, of which 26 were included in the review. RESULTS: The available evidence suggests that a three-zone model may be applicable defined by lactate thresholds (Aerobic Threshold (AeT) ≈ 1 mmol/L lactate/Anaerobic Threshold (AnT) ≈ 3-6 mmol/L lactate), which are broadly associated with, respectively, the ventilatory thresholds Gas Exchange Threshold (GET) and Respiratory Compensation Point (RCP). Zone 1 was characterized by values below 70% of maximal oxygen uptake (VO2max) and heart rate (HRmax) between 50-74%; Zone 2 ranged between 70-83% VO2max and 74-81% HRmax; and Zone 3 was defined as >83% VO2max and between 81-100% HRmax. In addition, MLSS and CS corresponded to higher exercise intensities than AnT (≈87-90% and ≈92% VO2max, respectively, versus ≈83% for AnT) were generally located within Zone 3, although MLSS has also been proposed as a marker close to the boundary between Zones 2 and 3. CONCLUSION: The scientific evidence analysed shows that, despite the diversity of physiological variables and protocols used in swimming, there is a general trend toward a three-zone training-intensity framework.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Anaerobic Speed Reserve and Critical Speed as Predictors of 200 m Front Crawl Performance: A Practical Alternative to Physiological Testing in Trained SwimmersEuropean Journal of Sport Science · 2026
- Acute Effects of Two Warm‐Up Protocols on Sprint Interval Swimming Performance and Physiological Responses in Trained Athletes: Implications for Swimming Training PracticeEuropean Journal of Sport Science · 2026
- Dmax-derived lactate-threshold intensity profiles and associated factors in adolescent swimmers: a multicenter cross-sectional study.Frontiers in physiology · 2026
- Collective case study on periodized training in elite female middle- and long-distance swimmers preparing for national competition.Frontiers in physiology · 2026
- From discrete classification to continuous space: compositional analysis reveals training intensity distribution migration across competition cycles in competitive swimmers.Frontiers in physiology · 2026
- Muscle oxygenation in competitive swimming: a roadmap for validating key performance indicatorsFrontiers in Sports and Active Living · 2026