Comparative oxidative and inflammatory responses to heated tobacco aerosol and cigarette smoke extracts in human lung fibroblasts.
Xylia Annisa Abelia, Ronny Lesmana, Melisa Intan Barliana, Massimo Caruso, Riccardo Polosa
Doctoral Program in Pharmacy, Faculty of Pharmacy, Universitas Padjadjaran, Bandung, Indonesia. · Department of Physiology, Faculty of Medicine, Universitas Padjadjaran, Bandung, Indonesia.
Key points
From the paper's conclusion- Methods MRC-5 human lung fibroblasts were exposed to aqueous cigarette smoke extract (CSE; 0.1–1.0 puffs/mL) or heated tobacco aerosol extract (HTE; 1.5–5.5 puffs/mL for viability, 3.0–5.5 puffs/mL for other endpoints).
Abstract
INTRODUCTION: Combustible cigarette smoke induces oxidative stress and inflammation in lung cells. Heated tobacco products (HTPs) have been proposed as alternatives with reduced toxicant emissions, but their cellular effects remain incompletely characterized. METHODS: MRC-5 human lung fibroblasts were exposed to aqueous cigarette smoke extract (CSE; 0.1-1.0 puffs/mL) or heated tobacco aerosol extract (HTE; 1.5-5.5 puffs/mL for viability, 3.0-5.5 puffs/mL for other endpoints). Concentrations were anchored to each product's 24 h IC50 (CSE 0.70 puffs/mL, 95% CI 0.63-0.77; HTE 4.76 puffs/mL, 95% CI 4.39-5.16). Cytotoxicity, oxidation-sensitive dihydroethidium (DHE) fluorescence, intracellular TNF-α and IL-6, and morphology were assessed. ATG5 protein was included as an exploratory endpoint. RESULTS: Both extracts increased DHE fluorescence and intracellular TNF-α and IL-6 in a concentration-dependent manner, with reduced viability and morphological changes. ATG5 findings were inconclusive, as no concentration differed from the untreated control. Nominal puff concentrations were not considered equivalent doses. In an exploratory comparison near each product's 24 h IC50 (CSE 0.7 and HTE 4.75 puffs/mL), CSE produced greater DHE fluorescence (3.17- versus 2.31-fold over vehicle) and greater intracellular IL-6 and TNF-α signals than HTE. Equivalent viability at the 90 min and 4 h endpoints was not established. DISCUSSION: Under these study-specific conditions, HTE elicited quantitatively smaller oxidative and inflammatory responses than CSE at the selected comparison concentrations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cardiovascular and metabolic acute effects of heated tobacco products in healthy smokersEuropean Journal of Preventive Cardiology · 2026
- Assessment of a novel heated non-tobacco product versus the 1R6F reference cigarette: A comparative study.Current research in toxicology · 2026
- The chemical profile and toxicological impact of heated tobacco productsInhalation Toxicology · 2026
- Heated cigarette smoke extract induces oxidative stress and remodels lipid signatures of the extracellular vesicle released by bronchial epithelial cells.Toxicology · 2026
- High-Content Screening Comparison of 1R6F Cigarette Smoke Extract and Selected Heated Tobacco and Electronic Vapour Product Aerosol Extracts in Endothelial and Bronchial Epithelial Cell Models.Journal of applied toxicology : JAT · 2026
- Toxicity of tobacco products and nicotine on neutrophil host defense: an in vivo and in vitro approach.Toxicology · 2026