Clinical correlation of hemodynamic parameters using blood flow prediction model in cerebrovascular arteries.
Jun Yup Kim, Wheesung Lee, Young-Lin Yoo, Da Hyun Lee, Si Un Lee, Beom Joon Kim, Jihoon Kang, Chae-Yong Kim,
Department of Neurology, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Republic of Korea. · NEAR Brain Inc., Seoul, Republic of Korea.
Key points
From the paper's conclusion- Discussion These findings indicate that DNF is a feasible approach for cerebrovascular hemodynamic assessment.
Abstract
INTRODUCTION: Patient-specific hemodynamic assessment is pivotal for optimizing treatment strategies in cerebrovascular interventions; however, conventional modalities are often limited by restricted clinical accessibility or prolonged acquisition times. METHODS: This study evaluates the previously developed Dr. NEAR flow (DNF), a streamlined computational framework designed for rapid and clinically feasible blood flow prediction, validated against Non-invasive Optimal Vessel Analysis (NOVA), a quantitative magnetic resonance angiography technique. The DNF methodology reconstructs a one-dimensional vascular topology from standard time-of-flight magnetic resonance angiography (MRA-TOF) sequences, and flow rate, velocity, and relative pressure are computed throughout the reconstructed vascular network using a Poiseuille-based fluid model. For validation, patient-specific boundary conditions were parameterized using proximal inflow measurements obtained from NOVA, and quantitative comparisons were performed at arterial locations with corresponding NOVA measurements. RESULTS: Across 230 arterial segments in 35 subjects, NOVA-measured and DNF-predicted flow rates were strongly correlated (r = 0.77), and the association remained significant after accounting for within-patient clustering (β = 0.863, 95% CI 0.769-0.957). Repeated-measures Bland-Altman analysis showed a mean bias (-58.04 mm³/s). After conversion of flow rates to velocities, vessel-averaged distributions across the major cerebral arteries showed generally similar patterns between the two modalities, although artery-specific correlations were variable. DISCUSSION: These findings indicate that DNF is a feasible approach for cerebrovascular hemodynamic assessment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Feature-Based Fusion of Angiography Videos and Blood Parameters for Fractional Flow Reserve (FFR) Prediction.Diagnostics (Basel, Switzerland) · 2026
- FlowPredictor-Corrector: A Hemodynamics-Guided Two-Step Deep Learning Framework for Vascular Flow Prediction.IEEE journal of biomedical and health informatics · 2026
- Theoretical derivation of blood velocity from TOF-MRA based artery centerline.ArXiv · 2026
- Deep operator learning for blood flow modelling in stenosed vesselsnpj Artificial Intelligence · 2025
- Estimation of Blood Velocity from TOF-MRA Arterial Centerlines: Theory, Simulation, and Inverse Solution.Bioengineering (Basel, Switzerland) · 2026
- A Subject-Specific Cerebrovascular CFD Modeling Approach Based on a Multimodal Data-Driven Boundary Calibration Framework: A Proof-of-Concept Study.Bioengineering (Basel, Switzerland) · 2026