Explainable deep learning-based classification of Wolff-Parkinson-White electrocardiographic signals.
Alice Ragonesi, Stefania Fresca, Karli Gillette, Stefan Kurath-Koller, Gernot Plank, Elena Zappon
Department of Mechanical Engineering, University of Washington, Seattle, WA, United States. · Division of Biophysics and Medical Physics, Gottfried Schatz Research Center, Medical University of Graz, Graz, Austria.
Key points
From the paper's conclusion- On the considered single heart geometry, our model achieves a localization accuracy above 94% and an average F1 score over 93%. XAI outputs are physiologically validated against known depolarization patterns, and a novel index is introduced to identify the most informative ECG leads for AP localization.
Abstract
INTRODUCTION: Wolff-Parkinson-White (WPW) syndrome is a cardiac electrophysiology (EP) disorder caused by the presence of an accessory pathway (AP) that bypasses the atrioventricular node, faster ventricular activation rate, and provides a substrate for atrio-ventricular reentrant tachycardia (AVRT). Accurate localization of the AP is critical for planning and guiding catheter ablation procedures. While traditional diagnostic tree (DT) methods and more recent machine learning (ML) approaches have been proposed to predict AP location from surface electrocardiogram (ECG), they are often constrained by limited anatomical localization resolution, poor interpretability, and the use of small clinical datasets. METHODS: In this preliminary patient-specific study, we present a Deep Learning (DL) model for the localization of single manifest APs across 24 cardiac regions, trained on a large, physiologically realistic database of synthetic ECGs generated using a personalized virtual heart model. We also integrate eXplainable Artificial Intelligence (XAI) methods, Guided Backpropagation, Grad-CAM, and Guided Grad-CAM, into the pipeline. This enables interpretation of DL decision-making and addresses one of the main barriers to clinical adoption: lack of transparency in ML predictions. RESULTS: On the considered single heart geometry, our model achieves a localization accuracy above 94% and an average F1 score over 93%. XAI outputs are physiologically validated against known depolarization patterns, and a novel index is introduced to identify the most informative ECG leads for AP localization. DISCUSSION: Results highlight lead V2 as the most critical, followed by aVR, and aVL in the left ventricle (LV) and V1 in the right ventricle (RV). This work demonstrates the potential of combining cardiac digital twins with explainable DL to enable accurate, transparent, and noninvasive AP localization.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- ECG-XPLAIM: eXPlainable Locally-adaptive Artificial Intelligence Model for arrhythmia detection from large-scale electrocardiogram dataFrontiers in Cardiovascular Medicine · 2025
- IECG: Weakly-Supervised Interpretability-Enhancing Foundation Model for ElectrocardiogramarXiv · 2026
- Diagnostic Accuracy of 12-Lead ECG Algorithms for Accessory Pathway Localization in WPW: A Meta-Analysis.Pacing and clinical electrophysiology : PACE · 2026
- Deep learning ECG detection of wall motion abnormalities suggesting silent coronary artery diseaseEuropean Heart Journal · 2026
- I-GraphECG: Observability-Based Lead Selection and Interpretable Disease Prediction from the 12-Lead ECG Using a Gray-Box Graph Electrophysiology Surrogate.Sensors (Basel, Switzerland) · 2026
- XAI-ECGNet: an explainable hybrid CNN-BiLSTM framework for multi-label cardiac diagnosis classification from 12-lead ECG signals using the PTB-XL datasetScientific Reports · 2026