Quantifying gravity-dependent and gravity-independent ventilation distribution by hyperpolarized 129Xe MRI in restrictive and airway diseases
Kunyu Du, David Mummy, Robert Tighe, Loretta Que, Bastiaan Driehuys, Yuh-Chin T. Huang
Duke University · Duke Medical Center
Key points
From the paper's conclusion- We divided the lung regions equally into apical/middle/basal compartments (gravity independent) and anterior/middle/posterior compartments (gravity dependent).
Abstract
Rationale Hyperpolarized 129 XeMRI can be used to quantify ventilation heterogeneity. The radio-frequency bias correction method has been shown to preserve the physiological ventilation gradient in healthy individuals. In this study, we tested the hypothesis that idiopathic pulmonary fibrosis (IPF) and obese asthma would have worsened gravity-dependent and gravity-independent ventilation distribution gradients. Methods We analyzed 3-dimensional HPXeMRI ventilation images from our databank using both the conventional N4ITK and the RF bias correction methods. We divided the lung regions equally into apical/middle/basal compartments (gravity independent) and anterior/middle/posterior compartments (gravity dependent). We averaged the ventilation signals within each compartment and calculated ventilation differences (Δ V ˙ ) between basal and apical compartments (Δ V ˙ B-A ) and between posterior and anterior compartments (Δ V ˙ P-A ). Results We included 10 younger (age: 23 ± 3 years), 10 older healthy subjects (age: 62 ± 7 years), 30 patients with idiopathic pulmonary fibrosis (IPF) (age: 74 ± 6 years) and 10 obese asthma patients (age: 40 ± 10 years). Younger and older healthy subjects had greater ventilation in the basal compartment (Δ V ˙ B-A =0.20 ± 0.17 and 0.11 ± 0.15 respectively) and the posterior compartment (Δ V ˙ P-A =0.08 ± 0.06 and 0.13 ± 0.16 respectively). Twenty-five IPF patients had positive Δ V ˙ B-A (0.17 ± 0.08) and Δ V ˙ P-A (0.11 ± 0.07). Five patients had negative Δ V ˙ P-A (-0.17 ± 0.09, p<0.0001) with three also having negative Δ V ˙ B-A (-0.04 ± 0.01, p=0.049). Six obese asthma patients had positive Δ V ˙ P-A (0.13 ± 0.08). Four patients had negative Δ V ˙ P-A (-0.11 ± 0.15, p=0.017) with two also having negative Δ V ˙ B-A (-0.17 and -0.09). Conclusions With the RF depolarization bias correction method, we showed physiological ventilation gradients in healthy subjects and detected abnormal (inverse) ventilation gradients in a subgroup of patients with IPF and obese asthma, despite low ventilation defect percentage (VDP), and mild or no spirometry abnormalities. The abnormal ventilation gradients may reflect the heterogeneity of the disease that may be associated with different treatment response and prognosis. These will need to be explored in future studies with a different design including larger populations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Hyperpolarized Xenon 129 MRI to Evaluate Regional Gas-Exchange Abnormalities in Cystic Fibrosis Lung Disease.Radiology. Cardiothoracic imaging · 2026
- Explainable artificial intelligence-based classification of asthma and COPD from xenon-129 ventilation magnetic resonance imaging.ERJ open research · 2026
- Hyperpolarized 129Xe MRI in Pediatric Hematopoietic Stem Cell Transplant Recipients With and Without Bronchiolitis Obliterans Syndrome.Pediatric pulmonology · 2026
- Can explainable artificial intelligence classify asthma and COPD from xenon-129 ventilation magnetic resonance imaging?ERJ open research · 2026
- Electrical Impedance Tomography Accurately Reflects Regional Ventilation Distribution Compared With Computed Tomography in Non-Intubated SubjectsRespiratory Care · 2026
- Effect of Visualized Respiratory Training on Patient Cooperation and Image Quality in Gadoxetic Acid Disodium‐Enhanced Liver MRI : A Randomized Controlled TrialJournal of Magnetic Resonance Imaging · 2026