科研速览 · Science Skim继续刷下去 · Keep skimming →
◆ European journal of applied physiology2026-08-17

Visually identified breakpoints in muscle oxygen saturation are not equivalent to ventilatory thresholds in national-level triathletes.

Ignacio Fernández-Jarillo, Jordi Montraveta, Xavier Iglesias, Chris McManus, Philip Skotzke, Diego Chaverri

一句话结论 · In one sentence

In this sample, SmO2 breakpoints did not fullfill criterion validity against ventilatory thresholds and therefore should not be used for determining exercise intensity domains. Further research should evaluate their equivalence using robust detection methodologies in larger samples.

原始摘要(英文原文)· Original abstract
PURPOSE: Portable near-infrared spectroscopy (NIRS) enables cost-effective monitoring of muscle oxygen saturation (SmO2) during exercise, presenting a promising alternative for delineating exercise intensity domains. This study investigated whether SmO2 breakpoints (BP1 and BP2) can provide accurate estimates of ventilatory thresholds (GET and RCP). METHODS: Twelve male Tier 3 triathletes completed an outdoor incremental TestVAM. Vastus lateralis SmO2 was recorded using NIRS, alongside pulmonary gas exchange measurements. BP1 and BP2 were identified visually. Heart rate (HR) and running speed at BP1, BP2, GET, and RCP were extracted. The intraclass-correlation coefficient (ICC) was calculated and equivalence between SmO2 breakpoints and ventilatory thresholds was assessed with equivalence bounds set at 5 bpm for HR and 0.5 km h-1 for speed. RESULTS: The ICC(3,1)abs was poor to moderate for all comparisons (range: 0.18-0.69). HR and speed between BP1 and GET were not equivalent (p > 0.91), with GET occuring ealier in both HR (p = 0.014, Δ = - 9.92 bpm, 90% CI [ - 16, - 3.83]) and speed (p = 0.007, Δ = - 1.29 km h-1, 90% CI [ - 1.99, - 0.59]). Similarly, BP2 and RCP were not equivalent (p > 0.98), and both HR (Δ = - 9.3 bpm, 90% CI [ - 12.18, - 6.42]) and speed (Δ = - 1.75 km·h-1, 90% CI [ - 2.33, - 1.17]) occuring earlier at RCP (p < 0.001). CONCLUSION: In this sample, SmO2 breakpoints did not fullfill criterion validity against ventilatory thresholds and therefore should not be used for determining exercise intensity domains. Further research should evaluate their equivalence using robust detection methodologies in larger samples.
读原文 · Read the paper ↗

AI 追问PRO

登录后使用 AI 追问

讨论区

登录后参与讨论

相关论文 · Related

Visually identified breakpoints in muscle oxygen saturation are not equivalent to ventilatory thresholds in national-level triathletes. — 科研速览 Science Skim