Artificial intelligence for chordee measurement in hypospadias surgery: current evidence and a blinded expert-panel validation framework.
Yusuf Atakan Baltrak, Hasan Deliaga
Department of Pediatric Urology, Adana City Training and Research Hospital, Adana, Türkiye. · Department of Pediatric Urology, Bursa Yuksek Ihtisas Training and Research Hospital, University of Health Sciences, Bursa, Türkiye.
Key points
From the paper's conclusion- At present, artificial intelligence should be considered a measurement aid for documentation, quality improvement, and decision support, not a replacement for expert surgical judgment.
Abstract
Hypospadias-associated ventral penile curvature, commonly referred to as chordee, is a key intraoperative finding that can influence the choice of straightening technique and the need for urethral plate preservation or transection. In routine surgery, curvature is usually estimated visually during artificial erection testing, but this approach is subjective and may vary according to surgeon experience, viewing angle, erection quality, penile rotation, and image perspective. Artificial intelligence and computer vision methods may provide a more objective and reproducible way to measure curvature from standardized operative images. Early studies have used object detection, segmentation, landmark detection, Hough-transform methods, circle fitting, and geometric angle calculation. Reported technical performance is promising, particularly in controlled model-based datasets, but the clinical evidence remains limited because real intraoperative images are heterogeneous and because reference standards vary across studies. This Review summarizes the current evidence for artificial intelligence-based penile curvature measurement in hypospadias surgery and proposes a practical validation framework for future clinical studies. The most important next step is not simply improving model accuracy, but testing locked models on standardized real intraoperative images using patient-level data separation, blinded expert-panel measurements, threshold-focused analysis around 30 degrees, and direct comparison with the operating surgeon's live estimate. At present, artificial intelligence should be considered a measurement aid for documentation, quality improvement, and decision support, not a replacement for expert surgical judgment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical translation of artificial intelligence in hypospadias: a systematic review and meta-analysis.Pediatric surgery international · 2026
- Artificial Intelligence-Based Lower-Limb Alignment Measurement in Pediatric and Adult Patients: Clinical Validation of Automated and Physician-Supervised Workflows.Children (Basel, Switzerland) · 2026
- An Artificial Intelligence-Based Preoperative Planning System for High Tibial Osteotomy Significantly Enhances Planning Speed With Comparable Accuracy to Surgeons.Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association · 2026
- AI-driven Assessment of Vertebral Rotation in Adolescent Idiopathic Scoliosis Using Weight-bearing Cone-beam CT.Academic radiology · 2026
- AI model predicts patient outcomes from surgical gestures and provides insights into explainabilitynpj Digital Surgery · 2026
- Enhancing Medical Students' Disease Detection Skills: Leveraging Artificial Intelligence Software for Diagnosing Developmental Dysplasia Using Ultrasound Imaging.Diagnostics (Basel, Switzerland) · 2026