Fetal intestinal dilatation and digestive tract abnormalities: an analysis of 94 cases from 16,090 deliveries in eastern Tianjin.
Shaohua Wang, Xinying Zhou, Ruifang Chen, Linxue Guan, Wenxiao Wen, Shanshan Zhao
The Third Central Hospital of Tianjin, Tianjin Key Laboratory of Extracorporeal Life Support for Critical Diseases, Artificial Cell Engineering Technology Research Centre, Tianjin Institute of Hepatobiliary Disease, Tianjin, China.
Key points
From the paper's conclusion- Isolated late-gestation FID has limited diagnostic specificity for structural gastrointestinal abnormalities, with high false-positive rates. These findings emphasize the need for cautious prenatal counseling and systematic postnatal evaluation. The proposed ultrasound assessment framework represents preliminary findings requiring prospective validation.
Abstract
BACKGROUND: Prenatal detection of fetal intestinal dilatation (FID) presents significant counseling challenges, particularly in late gestation when the distinction between structural and functional causes guides clinical management. This study evaluated the diagnostic performance of prenatal ultrasound for distinguishing structural from functional gastrointestinal abnormalities in a large cohort with postnatally confirmed diagnoses. METHODS: A retrospective analysis was conducted on 16,090 deliveries at a single tertiary center from January 2021 to May 2025. Ninety-four cases with prenatal FID were identified and followed postnatally. Diagnostic performance metrics (sensitivity, specificity, predictive values) were calculated, and ultrasound characteristics were compared between structural and functional cases. RESULTS: Among 94 FID cases, postnatal follow-up confirmed 27 (28.7%) structural abnormalities and 67 (71.3%) functional disorders. Prenatal ultrasound showed moderate sensitivity (63.0%, 95% CI: 43.9-79.3%) but low specificity (24.2%, 95% CI: 13.9-38.2%) for detecting structural anomalies. Isolated FID in late gestation (≥33 weeks) could not reliably distinguish structural from functional causes, with comparable detection rates (63.0% vs. 76.1%, P = 0.148) and similar intestinal diameters (median 1.72 vs. 1.85 cm, P = 0.147) between groups. ROC curve analysis confirmed poor predictive value of intestinal diameter alone (AUC = 0.413). CONCLUSION: Isolated late-gestation FID has limited diagnostic specificity for structural gastrointestinal abnormalities, with high false-positive rates. These findings emphasize the need for cautious prenatal counseling and systematic postnatal evaluation. The proposed ultrasound assessment framework represents preliminary findings requiring prospective validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Prenatal Ultrasound in Predicting the Need for Postnatal Surgery in Fetal Non-duodenal Small Bowel Dilation: A Systematic Review and Meta-Analysis.Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2026
- Prenatal Ultrasound Progression and Postnatal Retrospective Analysis of a Case of Small Intestinal Atresia with Volvulus.Diagnostics (Basel, Switzerland) · 2026
- Descriptive analysis of prenatal MRI features of pathologically confirmed enteric duplication cystsBMC Pediatrics · 2026
- Intra-abdominal Bowel Dilation in Experimental Gastroschisis Is Associated With a Modifiable Transcriptomic Program of Intestinal Dysfunction.Annals of surgery · 2026
- Maternal and Antenatal Complications in Pregnancies Complicated by Fetal Intra-Abdominal Umbilical Vein Varix.Journal of clinical medicine · 2026
- COMPREHENSIVE ASSESSMENT OF POTENTIAL EARLY MARKERS OF GASTROINTESTINAL DYSFUNCTION IN PRETERM INFANTS FROM TWIN PAIRS: A CLINICAL, LABORATORY, AND INSTRUMENTAL ANALYSISNeonatology surgery and perinatal medicine · 2026