Comparative accuracy of oro-helix length, naso-tragus length, and gestational age-based methods for endotracheal tube depth prediction in neonates ≤1,500 g.
Stergiani Agorastos, Wei Hou, Echezona T Maduekwe
Department of Pediatrics, Neonatology, Stony Brook Children's Hospital, Stony Brook, NY, United States. · Family, Population and Preventive Medicine, Stony Brook University Hospital, Stony Brook, NY, United States.
Key points
From the paper's conclusion- In neonates ≤1,500 g, OHL is the most accurate and reliable method for predicting ETT depth. OHL outperforms the NTL and GA tables based on CXR and thus may potentially be preferred approach for accurate ETT depth determination.
Abstract
OBJECTIVE: To evaluate the accuracy and reliability of the Oro-helix length (OHL), Naso-tragus length (NTL), and gestational age-based table (GA table) in predicting the ideal endotracheal tube (ETT) depth in neonates. STUDY DESIGN: This prospective study enrolled orally intubated neonates weighing ≤1,500 g admitted to a level IIIC neonatal intensive care unit (NICU) from April 2022 to February 2024. For each patient, the ETT insertion depths were predicted using OHL and NTL measurements, along with the GA table. To compare the accuracy of these methods, all predicted depths were assessed against the ideal depth determined by chest radiograph (CXR). Statistical analyses were conducted using a linear regression Bland-Altman model. RESULTS: Fifty were enrolled with a mean gestational age of 26.6 ± 1.5 weeks and a mean intubation weight of 953 ± 246.8 g. Among the three methods compared, NTL measurements demonstrated the greatest bias (-0.61 cm) and less agreement (-1.78 to 0.56 cm) than either OHL (-0.96 to 1.27 cm) or the GA table (-1.37 to 0.91 cm). OHL had the least bias (0.15 cm) and showed the strongest correlation with gestational age (slope = 0.09, R2 = 0.12, p = 0.02). In contrast, the correlations with gestational age for NTL and the GA table were weaker and not statistically significant (NTL: slope = 0.05, 95% CI: -0.02 to 0.13, R2 = 0.04, p = 0.16; GA table: slope = 0.02, 95% CI: -0.04 to 0.07, R2 = 0.01, p = 0.58). CONCLUSION: In neonates ≤1,500 g, OHL is the most accurate and reliable method for predicting ETT depth. OHL outperforms the NTL and GA tables based on CXR and thus may potentially be preferred approach for accurate ETT depth determination.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of Two Modified Nasal-Tragus Length Methods for Estimating Orotracheal Tube Depth in Thai Neonates: A Randomized Controlled Trial.Neonatology · 2026
- Comparing Subglottic Ultrasound and Distal Phalanx Width for Pediatric Endotracheal Tube Sizing in a Predominantly School-Aged Pediatric Cohort: A Prospective Study.Paediatric anaesthesia · 2026
- Development of an anthropometric-based algorithm to estimate feeding tube insertion depth in neonates.Journal of pediatric gastroenterology and nutrition · 2026
- Application of a combined predictive model based on lung ultrasound score trajectory changes in deciding mechanical ventilator weaning for neonatal respiratory distress syndrome: a retrospective studyFrontiers in Medicine · 2026
- Selection of endotracheal tube size and insertion depth according to pediatric growth charts and physique in Japan.Journal of anesthesia · 2026
- Early Changes in Optic Nerve Sheath Diameter Associated with Endotracheal Tube Versus Laryngeal Mask Airway in Children Undergoing Elective Surgery Under General Anesthesia: A Prospective Observational Study.Journal of clinical medicine · 2026