Frontiers in Ophthalmology

Biological characterization and bilateral intraocular concordance of near real surgical specimens: a human ex vivo platform for controlled intraocular research

Ryan W. Barrs, Mahita Kadmiel, Evan A. Ehrensing, Yoreh Barak, Vinit B. Mahajan, Dimitrios C. Arhontoulis, David R. P. Almeida

Key points

From the paper's conclusion
  • Conclusions NRSS specimens yielded viable retinal cells and measurable, bilaterally concordant vitreous H2O2 and IL-6.

Abstract

Background Experimental models of the human eye underpin vitreoretinal research and surgical training, and their value depends on how faithfully they preserve native tissue structure and biology. Existing human ex vivo models rely on isolated tissue segments or enucleated globes that do not preserve operative anatomy. Near Real Surgical Specimens (NRSS) are intact human donor head preparations in which both globes are retained in situ within the orbit, with native periocular anatomy and tissue relationships intact, prepared without aldehyde fixation. Prior work established the mechanical reproducibility of the platform. This study presents its first biological characterization and evaluates whether intraocular measurements are concordant between paired eyes. Methods Six NRSS specimens (12 eyes) from de-identified, research-consented donors were studied. Retinal explants from two specimens (four retinas) were mechanically dissociated, and membrane-intact viable cells were counted by trypan blue exclusion on a hemocytometer in two technical replicates per retina. Vitreous humor was assayed for hydrogen peroxide (H2O2) by fluorometric assay and for interleukin-6 (IL-6), tumor necrosis factor-alpha (TNF-α), and interleukin-1 beta (IL-1β) by sandwich ELISA. Bilateral agreement was assessed by intraclass correlation (ICC(A,1)), Bland-Altman analysis, and Pearson correlation, and intra-specimen and inter-specimen coefficients of variation (CV) were compared by Welch t-test. Results Mechanical dissociation yielded 15.8 to 24.3 ×10 6 membrane-intact viable cells per retina across four retinas. H2O2 was measurable in all 12 eyes (mean: 11.51 ± 2.67 μM; ICC(A,1) = 0.875; r = 0.943, p = 0.005). IL-6 was detectable in all 12 eyes (geometric mean: 34.0 pg/mL; ICC(A,1) = 0.917; r = 0.940, p = 0.005). Intra-specimen CV was significantly lower than inter-specimen CV for H2O2 (8.4 ± 5.3% vs. 19.2 ± 10.5%; p = 0.006) and IL-6 (31.9 ± 14.7% vs. 76.0 ± 29.0%; p = 0.0002). TNF-α was detectable in 2 of 12 eyes; IL-1β was undetectable. Conclusions NRSS specimens yielded viable retinal cells and measurable, bilaterally concordant vitreous H2O2 and IL-6. These findings provide the first biological characterization of the platform and support a paired-eye, contralateral-control design in which the fellow eye serves as a within-donor control. Extension to pharmacological and disease-modeling applications will follow further validation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Biological characterization and bilateral intraocular concordance of near real surgical specimens: a human ex vivo platform for controlled intraocular research — Science Skim