Biological characterization and bilateral intraocular concordance of near real surgical specimens: a human ex vivo platform for controlled intraocular research
Ryan W. Barrs, Mahita Kadmiel, Evan A. Ehrensing, Yoreh Barak, Vinit B. Mahajan, Dimitrios C. Arhontoulis, David R. P. Almeida
Key points
From the paper's conclusion- Conclusions NRSS specimens yielded viable retinal cells and measurable, bilaterally concordant vitreous H2O2 and IL-6.
Abstract
Background Experimental models of the human eye underpin vitreoretinal research and surgical training, and their value depends on how faithfully they preserve native tissue structure and biology. Existing human ex vivo models rely on isolated tissue segments or enucleated globes that do not preserve operative anatomy. Near Real Surgical Specimens (NRSS) are intact human donor head preparations in which both globes are retained in situ within the orbit, with native periocular anatomy and tissue relationships intact, prepared without aldehyde fixation. Prior work established the mechanical reproducibility of the platform. This study presents its first biological characterization and evaluates whether intraocular measurements are concordant between paired eyes. Methods Six NRSS specimens (12 eyes) from de-identified, research-consented donors were studied. Retinal explants from two specimens (four retinas) were mechanically dissociated, and membrane-intact viable cells were counted by trypan blue exclusion on a hemocytometer in two technical replicates per retina. Vitreous humor was assayed for hydrogen peroxide (H2O2) by fluorometric assay and for interleukin-6 (IL-6), tumor necrosis factor-alpha (TNF-α), and interleukin-1 beta (IL-1β) by sandwich ELISA. Bilateral agreement was assessed by intraclass correlation (ICC(A,1)), Bland-Altman analysis, and Pearson correlation, and intra-specimen and inter-specimen coefficients of variation (CV) were compared by Welch t-test. Results Mechanical dissociation yielded 15.8 to 24.3 ×10 6 membrane-intact viable cells per retina across four retinas. H2O2 was measurable in all 12 eyes (mean: 11.51 ± 2.67 μM; ICC(A,1) = 0.875; r = 0.943, p = 0.005). IL-6 was detectable in all 12 eyes (geometric mean: 34.0 pg/mL; ICC(A,1) = 0.917; r = 0.940, p = 0.005). Intra-specimen CV was significantly lower than inter-specimen CV for H2O2 (8.4 ± 5.3% vs. 19.2 ± 10.5%; p = 0.006) and IL-6 (31.9 ± 14.7% vs. 76.0 ± 29.0%; p = 0.0002). TNF-α was detectable in 2 of 12 eyes; IL-1β was undetectable. Conclusions NRSS specimens yielded viable retinal cells and measurable, bilaterally concordant vitreous H2O2 and IL-6. These findings provide the first biological characterization of the platform and support a paired-eye, contralateral-control design in which the fellow eye serves as a within-donor control. Extension to pharmacological and disease-modeling applications will follow further validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Validation of Optical Coherence Tomography Retinal Images of Raptor Eyes Using Confocal Laser Scanning MicroscopyVeterinary Ophthalmology · 2026
- Regional variations in the biomechanical properties of the isolated porcine retina: potential implications for subretinal injection.Experimental eye research · 2026
- Encapsulation and ocular inserts as strategies for topical ocular delivery of nobiletin: physicochemical characterization, ex vivo permeation, and biodistribution studies.Drug delivery and translational research · 2026
- Redox cycling of vitamins C and PEG-vitamin E preserves corneal integrity ex vivo during hypothermic storage.Tissue & cell · 2026
- Modeling ocular tissues with organoids: A review of techniques and applications in lacrimal gland, cornea, lens, and retina organoid.Stem cell reports · 2026
- Hydraulic Permeability of Retinal and Subretinal Layers: Experimental Quantification and Computational Modeling.Experimental eye research · 2026