Quantifying intratumor heterogeneity through MRI-based habitat analysis to distinguish HER2-low and HER2-zero triple-negative breast cancer
Jiayu Nan, Hao Li, Wei Zeng, Ao Wu, Yingyi Luo, Jiahui Jiang, Jiale Hu, Lan Liu
Key points
From the paper's conclusion- Background To evaluate whether magnetic resonance imaging (MRI)-derived intratumoral heterogeneity (ITH), quantified using habitat analysis, can distinguish human epidermal growth factor receptor 2 (HER2)-low from HER2-zero triple-negative breast cancer (TNBC), and to develop a combined model incorporating ITH, MRI features, and clinicopathological characteristics.
Abstract
Background To evaluate whether magnetic resonance imaging (MRI)-derived intratumoral heterogeneity (ITH), quantified using habitat analysis, can distinguish human epidermal growth factor receptor 2 (HER2)-low from HER2-zero triple-negative breast cancer (TNBC), and to develop a combined model incorporating ITH, MRI features, and clinicopathological characteristics. Methods This retrospective study included patients with surgically confirmed TNBC from two medical centers between April 2019 and September 2024. Center 1 provided the training cohort and center 2 provided the external validation cohort. Preoperative dynamic contrast-enhanced MRI (DCE-MRI) and clinicopathological data were collected. Habitat maps were generated by K-means clustering of peak-enhancement-phase images, and an ITH score was calculated from the spatial distribution of habitat regions. Logistic regression was used to develop an ITH-score model, a clinical-imaging model, and a combined model. Discrimination, calibration, and potential net benefit were evaluated. Results The study included 134 patients: 96 in the training cohort and 38 in the external validation cohort. The combined model achieved an area under the receiver operating characteristic curve (AUC) of 0.827 (95% confidence interval [CI]: 0.746–0.907) in the training cohort and 0.800 (95% CI: 0.660–0.940) in the validation cohort. Corresponding AUCs were 0.786 (95% CI: 0.695–0.876) and 0.769 (95% CI: 0.612–0.927) for the ITH-score model, and 0.712 (95% CI: 0.613–0.812) and 0.747 (95% CI: 0.595–0.900) for the clinical-imaging model. The combined model showed a numerically higher validation AUC, but the between-model differences were not statistically significant. Decision curve analysis suggested potential net benefit within the evaluated threshold ranges. Conclusions The combined model showed promising discrimination between HER2-low and HER2-zero TNBC. The small external validation cohort and wide confidence interval warrant cautious interpretation. Larger prospective studies are needed before the model can inform clinical decision-making.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- MRI ‐Based Habitat Analysis for Predicting Pathologic Complete Response to Neoadjuvant Chemotherapy in Breast Cancer: A Multicenter StudyJournal of Magnetic Resonance Imaging · 2026
- A SHAP-interpretable XGBoost model: MRI-based intratumoral perfusion heterogeneity predicts HER2-zero, -low, and -positive ternary expression status in breast cancerCancer Imaging · 2026
- Intratumoral heterogeneity derived from synthetic MRI for characterization of HER2 subtypes in breast cancer.Frontiers in oncology · 2026
- Deciphering intratumoral heterogeneity: An interpretable radiopathologic framework for lymph node staging in early-stage cervical cancer.Medical oncology (Northwood, London, England) · 2026
- Prediction of Ki-67 Status in Breast Cancer Using a Habitat-Guided 2.5D Multiparametric MRI Deep Learning Model.Journal of computer assisted tomography · 2026
- Multiparametric MRI-derived Interpretable Habitat Radiomics for Preoperative Assessment of Tumor Budding Status in Breast Cancer.Academic radiology · 2026