Frontiers in Oncology

Quantitative computed tomography and radiomics as imaging biomarkers for immune checkpoint inhibitor-related pneumonitis: a systematic review of differential diagnosis

Nan Huang, Yifan Jia, Yanli Yang

Review

Key points

From the paper's conclusion
  • Background Quantitative computed tomography (CT) and radiomics may support differential diagnosis of established immune checkpoint inhibitor-related pneumonitis (CIP), but transportable accuracy and clinical utility remain uncertain.

Abstract

Background Quantitative computed tomography (CT) and radiomics may support differential diagnosis of established immune checkpoint inhibitor-related pneumonitis (CIP), but transportable accuracy and clinical utility remain uncertain. Methods Six databases were searched in June 2026, with a documented public-index update through 31 August 2026. Current etiologic attribution was distinguished from future-risk prediction. Revision-stage author assessments and final adjudication were supplemented by a complete 3,900-record disposition log. Abstracts and preprints were included as a distinct evidence stratum; the accuracy synthesis used full-length published reports. Risk of bias was reassessed using tailored Quality Assessment of Diagnostic Accuracy Studies, version 3 (QUADAS-3) at the accuracy-estimate level, with separate descriptive-study appraisal. Results The review includes 17 reports: 13 full-length publications (11 accuracy reports and two descriptive comparisons), three abstracts and one indexed preprint. One included abstract is a companion, without duplicate cohort counting. Twenty-one areas under the receiver operating-characteristic curve (AUCs) and 10 sensitivity/specificity pairs were appraised; 20 estimates had high risk and 11 had insufficient information. These estimates were not independent cohorts. Validation was predominantly internal; one report included mixed-institution rather than purely external validation. The only compatible patient-level CIP-versus-radiation-pneumonitis hold-out operating point involved 40 patients: sensitivity 0.75 (exact 95% CI 0.51–0.91) and specificity 0.60 (0.36–0.81). No meta-analysis was performed. Prospective artificial intelligence (AI)-assisted reader or management-benefit evaluation was not identified among included reports. Conclusions The evidence supports within-dataset discrimination, not established transportable diagnostic utility. Unavailable full texts, historical validation limitations and incomplete cross-source linkage constrain evidence completeness. Independent attribution, locked patient-level testing, genuinely external validation and prospective clinical-impact evaluation remain priorities.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers