Dosimetric impact of target volume anatomical parameters on radiotherapy after right-sided breast-conserving surgery.

Lu Zou, Zeping Deng, Xingliang Liao, Ling Duan, Xuefen Liu

Department of Oncology, The People's Hospital of Rongchang District, Chongqing, China. · Department of Pediatrics, Chongqing University Three Gorges Hospital, Chongqing, China.

Observational · n=33

Key points

From the paper's conclusion
  • Objective To investigate the dosimetric effects of target volume Anatomical Parameters on organ at risk (OAR) following breast-conserving surgery and subsequent radiotherapy in patients with right-sided breast cancer.

Abstract

OBJECTIVE: To investigate the dosimetric effects of target volume Anatomical Parameters on organ at risk (OAR) following breast-conserving surgery and subsequent radiotherapy in patients with right-sided breast cancer. METHODS: A retrospective study was conducted on 33 patients who underwent post-breast-conserving surgery radiotherapy. The transverse diameter (TD), oblique diameter (OD), and the ratio of transverse diameter to oblique diameter (TOR) were measured at the nipple-center plane for all patients. Bivariate Pearson correlation analysis was used to examine the effects of TD, OD, and TOR on V20Gy, V5Gy, Dmean of the affected lung; Dmean and V5Gy of heart; Dmean of the right coronary artery (RCA); Dmean of the left anterior descending artery (LAD); V5Gy of the contralateral lung; and Dmean of the contralateral breast. RESULTS: OD and TD showed significant correlations with V20Gy, V5Gy, and Dmean of the affected lung (0.5 < R < 0.7, P < 0.01); The TD was significantly correlated with Heart_Dmean (R = 0.58, P < 0.01), strongly correlated with RCA_Dmean (R = 0.45, P < 0.01), and strongly correlated with LAD_Dmean (R = 0.42, P < 0.05); The TOR was significantly correlated with Heart_Dmean (R = 0.47, P < 0.01), strongly correlated with LAD_Dmean (R = 0.47, P < 0.01). CONCLUSION: Exploratory observational thresholds from our cohort: target volume with TD >8.00 cm or OD >19.56 cm indicates higher lung dose risk; TD >8.00 cm or TOR >0.47 indicates higher cardiac dose risk. These thresholds were not optimized by ROC analysis and cannot be directly used for clinical risk stratification; prospective validation is needed. Clinical planning should minimize heart and lung radiation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers