Individualized VMAT lattice radiotherapy on a standard flattening-filter linear accelerator for advanced bulky tumors: a retrospective feasibility and early clinical experience.
Jingna Ji, Min Xiao, Yan Ding, Gangyang Yu, Qian Wang, Jing Xie, Lu Zhang
Department of Radiation Oncology, Hankou Hospital Affiliated with Wuhan University of Science and Technology (Wuhan Hankou Hospital), Wuhan, Hubei, China.
Key points
From the paper's conclusion- Personalized LRT on FF linacs was feasible and well tolerated, with encouraging early palliative benefit in this small, heterogeneous cohort, supporting prospective evaluation with standardized symptom-assessment tools.
Abstract
BACKGROUND: Advanced bulky tumors cause pain, hemorrhage, and functional impairment, but their volume, hypoxic core, and proximity to organs at risk limit dose escalation with conventional radiotherapy. Lattice radiotherapy (LRT) delivers ablative doses to intratumoral vertices while sparing peripheral tissue. We evaluated personalized LRT on standard flattening-filter (FF) linacs, alone or with radiotherapy. METHODS: Seven patients (8 sites) with advanced bulky tumors treated February-November 2025 using 6 MV VMAT in FF mode were retrospectively reviewed. LRT (1-5 fractions of 6-15 Gy) was individualized by performance status, prior therapy, and tumor geometry; additional radiotherapy was at physician discretion. Co-primary endpoints were symptom relief (NRS, analgesic use, tumor-related symptoms) and local disease control; acute toxicity was secondary. RESULTS: Median age was 69 years, median ECOG 2 (1-3), and mean tumor volume 370.7 cc (101.8-792.4 cc). All patients completed planned LRT. Symptom improvement occurred in 6 of 8 sites (75%), usually within two weeks. At median follow-up of 8 months (4-12), partial response (PR) was achieved in 5 of 8 sites (62.5%), stable disease (SD) in 2 (25.0%), and progressive disease (PD) in 1 (12.5%); the disease control rate (DCR = CR + PR + SD) was 7/8 (87.5%), with no complete response (CR) observed. Acute toxicity occurred in 3 patients (all grade 1-2, mainly fatigue and mild dermatitis); no grade ≥3 events occurred. CONCLUSION: Personalized LRT on FF linacs was feasible and well tolerated, with encouraging early palliative benefit in this small, heterogeneous cohort, supporting prospective evaluation with standardized symptom-assessment tools.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Lattice radiotherapy boost integrated with thoracic VMAT in bulky stage IIIB non-small cell lung cancer: a case report.Frontiers in oncology · 2026
- Lattice radiotherapy for bulky tumors: A practical clinical guide from evidence synthesis to linac-based implementation in diverse resource settings.Journal of cancer research and therapeutics · 2026
- Dosimetric feasibility of lattice radiotherapy for bulky tumors: a paired VMAT vs. helical tomotherapy comparison - the STRYKE trial.Frontiers in oncology · 2026
- Dosimetric comparison of pipe-joint versus conventional VMAT for lattice radiotherapy in bulky tumors: a retrospective planning study.Radiation oncology (London, England) · 2026
- A systematic evaluation of lattice radiation therapy: from automated vertex placement to dosimetric criteria.Physics in medicine and biology · 2026
- Lattice SFRT in a geriatric patient with an initially inoperable leg bulky sarcoma: case report and literature review.Frontiers in oncology · 2026