Unraveling the complexity of PD-L1 assays: a descriptive review of the methodology, scoring, and practical implications

Gilad W. Vainer, Sunil Badve, Pathmanathan Rajadurai, Fernando Augusto Soares, G. Viale, Reinhard Büttner, Shanthy Nuti, Jonathan Juco,

Hadassah Medical Center · Emory Healthcare

Review

Key points

From the paper's conclusion
  • In this descriptive review, we concisely summarize the methodology and scoring methods of each assay, as well as some of the challenges associated with real-world use of these assay systems.

Abstract

Purpose: Over the years, immune checkpoint inhibitors targeting the programmed cell death protein 1 (PD-1) and programmed cell death ligand 1 (PD-L1) axes have substantially improved clinical outcomes for patients with various types of cancer and stages. As a result, PD-L1 is the most recognized biomarker used to guide the selection of patients for treatment with anti-PD-(L)1 therapy. To date, there are 4 regulatory agency-approved and commercially available immunohistochemistry assays used to quantify PD-L1 tumor expression, with each assay approved for use with a specific PD-(L)1 inhibitor. In this descriptive review, we concisely summarize the methodology and scoring methods of each assay, as well as some of the challenges associated with real-world use of these assay systems. Results: Each assay system is optimized for specific therapies, with its own anti-PD-L1 antibody, protocol, scoring, and interpretation guidelines. Although the methodologies of the 4 PD-L1 immunohistochemistry assay systems are similar, differences in their antibody clones, protocol conditions, instrumentation, and scoring methods limit assay interchangeability. The assays are also highly sensitive; slight deviations to the protocol can increase the risk of misclassifying the PD-(L)1 tumor status of patients. As a result, pathologists are faced with choosing which assay to perform with a limited tumor sample as well as with the challenges associated with the scoring methods and differences in regional regulatory approvals and infrastructure. Conclusion: While the 4 approved PD-L1 immunohistochemistry assays provide clinical value, we offer pathologists suggestions to reduce the challenges associated with PD-L1 testing based on assay systems.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Unraveling the complexity of PD-L1 assays: a descriptive review of the methodology, scoring, and practical implications — Science Skim