Construction and empirical testing of a verifiable food safety complaint risk-triage model using human foods complaint system data from the United States Food and Drug Administration.
Jinming Chen
College of Food Science and Engineering, Shanxi Agricultural University, Taigu, Shanxi, China.
Key points
From the paper's conclusion- HFCS data can support reproducible complaint triage. The model is suitable for ordering reports for human review, whereas product-group contrasts and raw predicted probabilities require cautious interpretation and temporal or external validation.
Abstract
BACKGROUND: Food safety complaint systems contain large numbers of heterogeneous adverse-event reports, but surveillance use requires reproducible data sources and interpretable rules for ranking reports that may involve severe outcomes. OBJECTIVE: To construct and test a transparent case-level logistic triage model that assigns FDA Human Foods Complaint System (HFCS) reports an urgent-priority score for earlier human review. METHODS: The official HFCS quarterly workbook was downloaded from the FDA website on 2026-05-13, and case-based reports received from January 1, 2004 through December 31, 2025 were analyzed (n = 149,642). Predictors were derived from validated age and date fields, sex, suspected product descriptors, MedDRA preferred-term counts, symptom-domain indicators, report year, and event-to-receipt lag. Product-group proportions were summarized with unadjusted Wilson 95% confidence intervals and interpreted descriptively. A balanced logistic regression model was assessed on a stratified test set. RESULTS: Urgent-priority outcomes occurred in 47,093 reports (31.47%). Death appeared in 17,005 reports and hospitalization in 23,405. The hospitalization proportion was 24.9% (95% CI, 24.5-25.3%) among dietary-supplement reports and 18.2% (16.3-20.3%) among infant/baby-food reports; these unadjusted proportions were not interpreted as population risk differences. The model achieved an AUC of 0.723, PR-AUC of 0.526, Brier score of 0.214, Brier skill score of 0.008, a calibration intercept of -0.03, and a calibration slope of 0.91 on 37,411 test cases. Symptom count and the infant/baby-food indicator had the largest positive model weights. CONCLUSION: HFCS data can support reproducible complaint triage. The model is suitable for ordering reports for human review, whereas product-group contrasts and raw predicted probabilities require cautious interpretation and temporal or external validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Explainable Transformer-Based Modelling for Pathogen-Oriented Food Safety Inspection Grade Prediction Using New York State Open DataFoods · 2026
- Predicting food safety problems among catering service operators using longitudinal regulatory data.Journal of food protection · 2026
- Food-System Stress Testing: Prediction Tasks Under Alternative Outcome DefinitionsMathematics · 2026
- High-risk food recalls in the United States: Temporal trends and structural characteristics based on FDA enforcement data, 2012-2024.PloS one · 2026
- Calibrated AI approach to pharmacovigilance using FAERSnpj Digital Medicine · 2026
- Data Quality and Performance Classification in Multisectoral Nutrition Monitoring: A Composite Framework and Empirical Application.Current developments in nutrition · 2026