Modulation of [99mTc]Tc-iPSMA preparation conditions reduces radiochemical species heterogeneity and supports a single-vial cold-kit formulation
Jeanne Chillard, Lina Stamboul, Jade Torchio, Léa Rubira, Cyril Fersing
Key points
From the paper's conclusion- Conclusion Radio-HPLC-guided optimization markedly reduced radiochemical heterogeneity of [ 99m Tc]Tc-iPSMA while maintaining high RCP.
Abstract
Introduction Technetium-99 m labeling of hydrazinonicotinamide (HYNIC)-conjugated vectors requires transfer ligands and co-ligands that may generate multiple radiochemical species with slightly different physicochemical and biological properties. This study aimed to optimize the radiolabeling of the HYNIC-conjugated prostate-specific membrane antigen ligand iPSMA to reduce chromatographic heterogeneity while maintaining high radiochemical purity (RCP), and to translate the selected conditions into a single-vial cold-kit formulation. Methods Twenty radiolabeling conditions were evaluated through 3 replicates each by independently varying the co-ligand, transfer ligand, buffer, reducing agent, antioxidant, reaction time, and reaction temperature. Products were characterized by radio-HPLC and radio-TLC. The optimized conditions were subsequently applied to freeze-dried single-vial formulations containing one of five bulking agents. The effects of bulking-agent content, technetium-99 m activity, heating time, and pertechnetate eluate age were also investigated. Results The reference protocol yielded an RCP of 90.31 ± 0.83%, with the predominant radiolabeled species accounting for 76.97 ± 2.53% of the radiocomplexes. Among the investigated parameters, reaction-medium composition, particularly the buffer used, had the greatest influence on the chromatographic distribution of radiolabeled species. Using sodium acetate 0.2 M at pH 7 with EDDA and tricine increased RCP to 95.15 ± 0.29% and the proportion of the predominant radiolabeled species to 96.21 ± 0.23%. Reduced/hydrolyzed technetium remained below the radio-TLC detection limit. Mannitol provided the best cold-kit performance and was selected at 40 mg per vial. Under the present formulation conditions, satisfactory kit performance was obtained with ≤1.5 GBq of freshly eluted pertechnetate (<30 min), with 0.92 ± 0.11% residual pertechnetate, 91.47 ± 2.66% major radiolabeled species, and a RCP of 95.69 ± 1.28%. Conclusion Radio-HPLC-guided optimization markedly reduced radiochemical heterogeneity of [ 99m Tc]Tc-iPSMA while maintaining high RCP. The selected conditions could be translated into an all-in-one single-vial proof-of-concept formulation, although further analytical, pharmaceutical and biological development is required before clinical implementation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Design, Synthesis, and Evaluation of 99mTc-Labeled PSMA-Targeting Dimeric Tracers: Comparison of Glutamate-Urea-Lysine (EuK) and Aminoadipic Acid-Urea-Lysine (AuK) Targeting Groups.Journal of medicinal chemistry · 2026
- Design and 99mTc-radiolabeling of an imidazopyridine-hydrazone hybrid: A promising tumor-targeted radiopharmaceutical.Journal of pharmaceutical sciences · 2026
- Evaluation and an Exploratory Human Study of 99mTc-Labeled PSMA-Targeting Agents with Reduced Renal Uptake via Proline Incorporation.Journal of medicinal chemistry · 2026
- Amino acid-quinoline-engineered PSMA ligands for prostate cancer radiotheranostics.Bioorganic chemistry · 2026
- Optimizing [99mTc]Tc-Tamsulosin for Enhanced Tumor Detection: A Comprehensive Approach from Preparation to In Vivo EvaluationNuclear Medicine and Molecular Imaging · 2026
- PSMA binding of carbamate-containing peptidomimetics influenced by side chain length and stereocenter configuration in preclinical prostate cancer model.Bioorganic & medicinal chemistry · 2026