Localizing the epileptogenic zone in drug-resistant epilepsy based on ictal SEEG high-resolution time-frequency representation.
Genyu Fu, Shijie Chen, Danni Yang, Sixian Chan, Yalin Wang, Zhe Shi, Qiang Li
School of Information Science and Engineering, Lanzhou University, Lanzhou, China. · School of Materials Science and Engineering, Lanzhou University of Technology, Lanzhou, China.
Key points
From the paper's conclusion- Under subject-independent cross-validation, the optimal HFO-based method achieved an accuracy of 66.10 ± 1.40%, an F1-score of 49.49 ± 2.48% and an AUC of 67.95% ± 2.35%. By comparison, Superlets-VGG19 model achieved significantly better performance: an accuracy of 80.46 ± 4.61%, an F1-score of 79.52 ± 6.88% and an AUC of 80.06 ± 5.23%. Notably, the framework exhibited superior performance in the radiofrequency thermocoagulation (RFTC) sub-cohort, with an accuracy of 82.31 ± 3.41%, an F1-score of 82.56 ± 4.62%, and an AUC of 82.85 ± 3.80%.
Abstract
INTRODUCTION: Drug-resistant epilepsy (DRE) presents a critical clinical challenge, and accurate epileptogenic zone (EZ) localization is essential for successful surgical intervention. Stereoelectroencephalography (SEEG) is widely applied in clinical practice, but conventional visual inspection and high-frequency oscillations (HFOs) suffer from low efficiency, poor reproducibility, and insufficient representation of complex neural dynamics, failing to improve postsurgical seizure-free rates substantially. To address the limitations, we developed an automated EZ localization framework leveraging ictal SEEG high-resolution time-frequency representation (TFR) and convolutional neural network (CNN). METHODS: Twenty three adult individuals with DRE who achieved Engel Class I surgical outcomes were enrolled in this study. The TFRs of ictal SEEG (0.5-500 Hz) were generated using Short-Time Fourier Transform (STFT), Continuous Wavelet Transform (CWT), and Superlet Transform, then were classified by VGG16/19 and ResNet-18/34/50. RESULTS: Under subject-independent cross-validation, the optimal HFO-based method achieved an accuracy of 66.10 ± 1.40%, an F1-score of 49.49 ± 2.48% and an AUC of 67.95% ± 2.35%. By comparison, Superlets-VGG19 model achieved significantly better performance: an accuracy of 80.46 ± 4.61%, an F1-score of 79.52 ± 6.88% and an AUC of 80.06 ± 5.23%. Notably, the framework exhibited superior performance in the radiofrequency thermocoagulation (RFTC) sub-cohort, with an accuracy of 82.31 ± 3.41%, an F1-score of 82.56 ± 4.62%, and an AUC of 82.85 ± 3.80%. DISCUSSION: The proposed framework outperforms conventional HFO-based baselines and provides a reliable and objective tool for clinical EZ localization, and holds substantial optimization potential via integration of complex architectures such as Transformer and Mamba-based models.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Patient-Specific Non-Invasive Epileptogenic Zone Localization via High-Resolution Time-Frequency Representations and CNN Deep Learning.IEEE transactions on bio-medical engineering · 2026
- Localising the Seizure Onset Zone from Routine Interictal and Ictal Scalp EEG Via a Factorised Spatiotemporal Ensemble Deep Learning FrameworkbioRxiv · 2026
- Cross-Subject Localization of Epileptogenic Zone for Drug-Resistant Epilepsy Based on the Causal Brain Network.IEEE transactions on bio-medical engineering · 2026
- Non-invasive preoperative prediction of surgical outcomes in drug-resistant epilepsy using seizure-related EEG network dynamics.Frontiers in neuroscience · 2026
- Low-gamma wavelet entropy as a contextual signature descriptor of the epileptogenic zone in peri-onset SEEG.IEEE transactions on bio-medical engineering · 2026
- Seizure Onset Zone Localization in Drug-Resistant Epilepsy Using Self-Supervised Learning on Stereo-EEGmedRxiv · 2026