CLSP-REQA: a real-time quality-aware closed-loop seizure prediction framework with Mamba-BiLSTM and confidence-gated intervention.

Mufeng Chen, Qi Wu, Bingchao Huang, Xiwen Lai, Zekai Chen, Xinge Ouyang, Quansheng Ren

Department of Engineering Science, University of Oxford, Oxford, United Kingdom. · Mathematical Institute, University of Oxford, Oxford, United Kingdom.

Key points

From the paper's conclusion
  • We conducted dedicated experiments testing whether this learned score reflects genuine signal quality rather than a redundant proxy for the prediction task, and a sensitivity analysis of the fusion thresholds against standard calibration baselines.

Abstract

INTRODUCTION: Reliable seizure prediction is a prerequisite for closed-loop neurostimulation therapy, yet existing methods rarely account for the variability in EEG signal quality encountered in real-world deployment, and the overwhelming majority adopt non-strict evaluation protocols that overestimate generalization performance. METHODS: We propose CLSP-REQA (Closed-Loop Seizure Prediction with Real-time EEG Quality Assessment), a unified framework that embeds a lightweight signal quality estimator directly within the prediction pipeline. A Real-time EEG Quality Assessment (REQA) module runs in parallel with a Mamba-BiLSTM backbone, producing a scalar quality score q ∈ [0, 1] that modulates output confidence through a tiered non-linear fusion function (ECLO). We conducted dedicated experiments testing whether this learned score reflects genuine signal quality rather than a redundant proxy for the prediction task, and a sensitivity analysis of the fusion thresholds against standard calibration baselines. The framework was evaluated under strict cross-patient evaluation on the CHB-MIT Scalp EEG Database (n = 23 subjects, 198 seizures) and the SIENA Scalp EEG Database (n = 14 subjects, 47 seizures). RESULTS: On CHB-MIT, CLSP-REQA achieved an AUC-ROC of 0.7426 ± 0.0199, exceeding the unadapted cross-patient baseline of 0.69 reported by Jemal et al., using only 16 EEG channels compared to 23 in prior work, and without requiring any target-patient data or domain adaptation. On SIENA, CLSP-REQA achieved an AUC of 0.7012 ± 0.0249, exceeding the best domain-adapted cross-patient result of 0.61 on the same dataset under a strictly harder information constraint, since domain adaptation methods are given access to unlabelled target-patient data that CLSP-REQA does not use. DISCUSSION: The framework outputs a structured four-tuple 〈p, q, c, ΦSHAP〉 designed for compatibility with closed-loop neurostimulator interfaces. As both evaluation datasets are retrospective recordings from controlled hospital settings, we report this study as a feasibility demonstration rather than evidence of prospective, real-world clinical readiness, and the comparison with domain adaptation should not be read as unconditional superiority.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

CLSP-REQA: a real-time quality-aware closed-loop seizure prediction framework with Mamba-BiLSTM and confidence-gated intervention — Science Skim