Clinical facial weakness and multimodal electrophysiology in amyotrophic lateral sclerosis: motor unit number index, nerve conduction, and blink reflex
Yu Wang, Yanping Ren, Ju Zhu, Na Liu, Li Tian
Key points
From the paper's conclusion- Secondary and exploratory objectives related cheek-puff weakness to facial MUNIX, nerve conduction, blink reflex, and onset phenotype.
Abstract
Background Cheek-puff weakness is clinically recognised in amyotrophic lateral sclerosis (ALS), but its relation to non-invasive facial electrophysiology is uncertain. Objective The primary objective was to test whether participant-level orbicularis oris motor unit number index (MUNIX) was lower in ALS than in healthy controls after age and sex adjustment. Secondary and exploratory objectives related cheek-puff weakness to facial MUNIX, nerve conduction, blink reflex, and onset phenotype. Methods In this retrospective cross-sectional study, we analysed 43 patients with ALS, 25 healthy controls (Control A), and 42 peripheral vestibular disease controls (Control B). Results The adjusted primary MUNIX difference versus Control A was not significant ( β = −7.08; p = 0.153). Cheek-puff weakness was more frequent than eye-closure weakness (21/43 versus 4/43; exact McNemar p < 0.001) and was associated with lower orbicularis oris MUNIX after age and sex adjustment ( β = −13.09; p = 0.006). In limb-onset ALS, cheek-puff weakness remained associated with lower MUNIX after additional adjustment ( β = −17.40, 95% confidence interval −30.56 to −4.25; p = 0.011); only nine patients had bulbar-onset ALS, limiting comparison between onset groups. Orbicularis oris distal motor latency remained longer after adjustment ( p = 0.011), and R2 was abnormal in 11/39 patients versus 0/42 Control B participants ( p < 0.001). Conclusion Assessment of cheek puff and eye closure is relevant irrespective of ALS onset site. Orbicularis oris MUNIX was associated with clinically observed cheek-puff weakness but was not supported as a stand-alone ALS marker. Distal latency and R2 provided additional, largely non-overlapping information. Prospective validation against cranial-muscle electromyography and longitudinal bulbar outcomes is required.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison between ultrasound and electromyography for detection of fasciculations in amyotrophic lateral sclerosis: an updated systematic review and meta-analysis.Radiologia brasileira · 2026
- Translation of surface electromyography into a clinically applicable objective bulbar assessment tool to improve measurement-based care in amyotrophic laterals sclerosisFrontiers in Neuroscience · 2026
- Correlation between tongue ultrasound parameters and swallowing dysfunction in patients with amyotrophic lateral sclerosisBMC Neurology · 2026
- Phenotype-Related Characteristics of Tongue Motor Function in Amyotrophic Lateral Sclerosis: A Retrospective Comparative Study of Static and Dynamic Acoustic Measures.Folia phoniatrica et logopaedica : official organ of the International Association of Logopedics and Phoniatrics (IALP) · 2026
- Effects of fasudil on disease spreading in ALS - A MUNIX-based post-hoc analysis of the ROCK-ALS trialNeurotherapeutics · 2026
- Impaired discrimination of negative facial emotions in pure motor ALS.Journal of neurology · 2026