Frontiers in Neurology

Lightweight convolutional neural networks for detecting middle cerebral artery stenosis on TCD spectral images: discriminative performance, probability calibration and deployment value

Qian Zhao, Li Sun, Nannan Li, Xiaoping Zhang

Observational

Key points

From the paper's conclusion
  • Conclusion For TCD-based MCA stenosis detection, discrimination saturated across backbones spanning an order of magnitude in cost; in this single-center dataset, deployment cost therefore provided a pragmatic criterion for architecture selection rather than AUC.

Abstract

Background Transcranial Doppler (TCD) is a portable bedside tool for screening middle cerebral artery (MCA) stenosis, but its accuracy depends strongly on operator experience. Most reported deep-learning studies optimize one architecture and assess discrimination only, leaving open the architecture’s point-of-care cost and whether its output probability can be trusted. Methods In this retrospective single-center study, 1,835 TCD spectral images (1,641 development; 194 held-out) were analyzed per vessel-side image. Four backbones spanning a 7.7-fold parameter range—ResNet50, EfficientNet-B0, EfficientNetV2-S, MobileNetV3-Large—shared a head under unified fine-tuning. The candidate was chosen by a rule that fixes discrimination eligibility on development-cohort out-of-fold predictions and then ranks the eligible backbones by measured CPU cost, applied before any held-out-cohort scoring: lowest CPU latency among backbones whose development-cohort AUC was statistically indistinguishable from the best. Protocols used validation-only grid search; the loss was ablated; readiness was assessed via ECE, Brier, Murphy decomposition, Grad-CAM. Results All backbones showed statistically indistinguishable held-out discrimination (AUC 0.9995–0.9999; every paired bootstrap ΔAUC 95% CI included zero), while cost differed by an order of magnitude: MobileNetV3-Large used 7.7 × fewer parameters and 19 × fewer FLOPs than ResNet50, ran 1.6–9.5 × faster, and matched it within noise. The rule selected MobileNetV3-Large as primary (EfficientNet-B0 secondary); FLOPs did not predict CPU latency. Validation-only temperature scaling reduced ECE to 0.0102–0.0161; residual Brier was almost entirely reliability. Conclusion For TCD-based MCA stenosis detection, discrimination saturated across backbones spanning an order of magnitude in cost; in this single-center dataset, deployment cost therefore provided a pragmatic criterion for architecture selection rather than AUC. This single-center, single-device retrospective study does not establish external generalization; multicenter prospective validation formally remains required before clinical use.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Lightweight convolutional neural networks for detecting middle cerebral artery stenosis on TCD spectral images: discriminative performance, probability calibration and deployment value — Science Skim