Clinician evaluation of AI-generated summaries of responsive neurostimulation data
Gayal Kuruppu, Amerta Bai, Ajay Deep Kachhvah, Aisha Abdulrazaq, Zhiyi Sha, Adeel Ilyas, Abdulrahman Alwaki, Jay Gavvala,
Key points
From the paper's conclusion- These data are essential for therapy optimization but are technically complex, making them difficult to communicate to non-experts and time-intensive for epileptologists to convert into clinically interpretable, billable documentation.
Abstract
Introduction NeuroPace responsive neurostimulation (RNS) systems store longitudinal electrophysiological and device-programming data in the Patient Data Management System (PDMS). These data are essential for therapy optimization but are technically complex, making them difficult to communicate to non-experts and time-intensive for epileptologists to convert into clinically interpretable, billable documentation. We aimed to develop and evaluate an artificial intelligence (AI)-based framework that translates PDMS-derived RNS therapy data into clinically actionable summaries. Methods In this single-center study, a two-stage pipeline generated rule-based visit-level summaries for 30 randomly selected patients and Phi-4 large language model evolutionary summaries for a subset of 10. Eleven clinicians (six neurology residents and five epileptologists) rated summaries against source PDMS data on a 5-point Likert scale (3 = neutral) for accuracy, completeness, relevance, coherence, bias and toxicity. Evolutionary summaries were rated by epileptologists only and also for efficiency and clinical integration. Ratings were compared with neutral and between rater groups. Results Median ratings for all core domains were 4–5 for both summary types and exceeded neutral (all p < 0.001), with uniformly favorable bias and toxicity ratings. For visit-level summaries, residents rated accuracy, completeness and bias higher than epileptologists, although not significantly at the evaluator level. Conclusion In this exploratory study, clinicians rated AI-assisted RNS summaries favorably, although ratings tended to differ by clinical experience. The small sample and lack of objective ground-truth evaluation limit conclusions about factual accuracy and clinical utility. Larger prospective studies should assess whether this approach reduces documentation burden and supports scalable epilepsy care.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A report-supervised EEG-language foundation model enables broad, interactive clinical interpretationmedRxiv · 2026
- Automated Interpretation of EEG Reports Using a Large Language Model with Structured Confidence OutputsmedRxiv · 2026
- Artificial Intelligence Note Summarization in the Emergency DepartmentJAMA Network Open · 2026
- ERIA: An Instruction-Optimized Agent for Clinical EEG ReportingarXiv · 2026
- Clinician perspectives on explainability in AI-driven closed-loop neurotechnologyScientific Reports · 2025
- Automated Classification of Clinical EEG Reports as Normal or Pathological Using Natural Language Processing: A Multi-Centre StudymedRxiv · 2026