3D-printed patient-specific guides improve screw accuracy in upper cervical spine surgery: a comparative study.
Guoqi Niu, Yalong Guo, Gong Zhou, Yang Gao, Weili Jiang, Hui Chen, Hu Nie, Tao Liu,
Department of Orthopedics, The Second Affiliated Hospital of Bengbu Medical University, Bengbu, Anhui, China. · Department of Orthopedics, The Second Affiliated Hospital of Shandong First Medical University, Tai'an, China.
Key points
From the paper's conclusion- Patient-specific 3D-printed guide plates significantly improve screw placement accuracy and reduce operative time, blood loss, and radiation exposure in upper cervical spine surgery, while achieving clinical outcomes comparable to the free-hand technique. This method is a safe and effective alternative for upper cervical pedicle screw fixation.
Abstract
OBJECTIVE: To evaluate the feasibility and clinical efficacy of patient-specific 3D-printed guide plates for pedicle screw placement in the upper cervical spine, compared with the conventional free-hand technique. METHODS: A retrospective analysis was conducted on 39 patients who underwent upper cervical spine surgery between June 2009 and June 2022. Patients were divided into a guide plate group (n = 24) and a free-hand control group (n = 15). Surgical parameters (operative time, blood loss, fluoroscopy frequency), screw placement accuracy (assessed by Kawaguchi classification on postoperative CT), and clinical outcomes (VAS, JOA, and ASIA scores) were compared between groups. RESULTS: A total of 141 pedicle screws were placed. The guide plate group achieved a significantly higher rate of perfect screw placement (81.8 vs. 62.3%, P = 0.009) and fewer grade 2 cortical breaches. Operative time, blood loss, and fluoroscopy exposure were significantly reduced in the guide plate group (all P < 0.05). Both groups showed significant postoperative improvements in all clinical scores (P < 0.05), with no significant intergroup differences at final follow-up. CONCLUSION: Patient-specific 3D-printed guide plates significantly improve screw placement accuracy and reduce operative time, blood loss, and radiation exposure in upper cervical spine surgery, while achieving clinical outcomes comparable to the free-hand technique. This method is a safe and effective alternative for upper cervical pedicle screw fixation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Clinical application of a dual-surface, four-edge 3D-printed pedicle screw guide in adolescent idiopathic scoliosis surgery: a retrospective comparative study.Journal of orthopaedic surgery and research · 2026
- Clinical outcome and implant accuracy in cervical fractures stabilization using 3D-printed patient-specific drill guides for placement of bicortical screws in 16 dogsFrontiers in Veterinary Science · 2026
- Accuracy and safety of individualized 3D-printed guides for L4 pedicle screw placement: An in vitro comparison with the free-hand technique.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026
- 3D-Printed Guides, Navigation, and Robotic Assistance in Spinal Instrumentation: A Network Meta-Analysis of Pedicle Screw Accuracy and Clinical Outcomes.The spine journal : official journal of the North American Spine Society · 2026
- Immediate performance effects of 3D-printed guide plate-assisted screw placement training in lumbar spine models: a randomized educational study.BMC medical education · 2026
- Clinical Application of Surgical Guides in MARPE: Observational Research.Journal of clinical medicine · 2026