Frontiers in neurorobotics

Reliability-aware multimodal sensor fusion for human motion monitoring with safety-constrained neurorobotic feedback in sports training.

Feng Xu, Wuyi Zhu, Jiaoyu Wang

Department of Physical Education, Bengbu University, Bengbu, Anhui, China. · Sports Department, Hefei University of Technology, Hefei, Anhui, China.

Computational

Key points

From the paper's conclusion
  • Across the 10 held-out virtual-athlete profiles, accuracy is 0.870 ± 0.086 with a cluster-bootstrap 95% confidence interval of 0.820–0.920.

Abstract

INTRODUCTION: Embodied intelligent systems require reliable perception and safety-constrained feedback mechanisms for human motion understanding under heterogeneous sensing conditions. In this study, volleyball training is considered as a representative dynamic human-motion scenario rather than the sole application objective. The proposed system aims to provide a general neurorobotic perception and feedback framework for complex embodied environments. The framework must infer rapid technical actions while simultaneously tracking fatigue, jump loading, context information, and sensor reliability. METHODS: This study presents an embodied neurorobotic framework that combines a reliability-aware sensor-fusion transformer with a bidirectional long short-term memory (BiLSTM) estimator. Inertial, pose, plantar-pressure, ultra-wideband, and physiological measurements are synchronized, quality-gated, and exchanged through cross-modal attention before bidirectional temporal reasoning produces action, fatigue, and load estimates. The framework further couples these estimates to a barrier-based safety projection for haptic or robotic feedback. Theoretical analysis establishes a cross-modal perturbation bound and a conditional one-step barrier-satisfaction result under bounded estimation error, bounded disturbance, and maintained projection feasibility. Experiments use an athlete-disjoint, fully reproducible synthetic benchmark with controlled sensor noise and missing-modality conditions. RESULTS: The complete model achieves 87.0% accuracy and 0.872 macro-F1, exceeding transformer-only, BiLSTM-only, and no-quality-gate variants. Across the 10 held-out virtual-athlete profiles, accuracy is 0.870 ± 0.086 with a cluster-bootstrap 95% confidence interval of 0.820-0.920. Robustness tests show graceful degradation under moderate corruption, while the illustrative safety-filter simulation prevents all boundary violations observed under the unconstrained policy. DISCUSSION: Because no human-subject volleyball data are used, these findings establish reproducible computational behavior rather than field safety, injury-prevention efficacy, or clinical validity.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers