Frontiers in molecular biosciences

Identification of candidate inverse miRNA-mRNA pairs and an internally validated tissue-based diagnostic model for benign and malignant breast lesions.

Xiaoyan Zhao, Hui Feng, Xingxing Wu, Dan Zhao

Department of Breast Surgery, Shanxi Provincial Children's Hospital, Shanxi Provincial Maternity and Child Healthcare Hospital, Taiyuan, Shanxi, China. · Department of Breast Surgery, Taiyuan Maternal and Child Health Hospital, Taiyuan, Shanxi, China.

Observational

Key points

From the paper's conclusion
  • Conclusion A five-marker tissue model discriminated benign from malignant breast lesions in internal validation. miR-205-5p/HMGB3 and miR-96-5p/FOXO1 were the leading inverse-expression candidates.

Abstract

BACKGROUND: Differentiating malignant breast tumors from benign breast lesions remains clinically important when imaging or pathology is indeterminate. We evaluated candidate inverse miRNA-mRNA expression pairs as a tissue-based adjunctive molecular approach intended to complement, not replace, histopathological diagnosis, with particular relevance to diagnostically challenging lesions such as BI-RADS four or radiologic-pathologic discordant cases. METHODS: Public microRNA (miRNA) and messenger RNA (mRNA) datasets were used for candidate discovery and prioritization. An independent reverse-transcription quantitative polymerase chain reaction (RT-qPCR) tissue cohort included 150 breast-lesion samples (68 benign and 82 malignant). Ten candidate axes were measured. A least absolute shrinkage and selection operator (LASSO) logistic-regression model was developed in the training cohort and tested without marker reselection, coefficient refitting, or threshold re-optimization in the internal-validation cohort. Public datasets were used primarily for tumor-versus-normal discovery, whereas benign-versus-malignant evaluation was performed in the independent tissue cohort. RESULTS: miR-205-5p/HMGB3 and miR-96-5p/FOXO1 showed the strongest inverse-expression candidate evidence. The final model retained miR-205-5p, HMGB3, miR-96-5p, FOXO1, and miR-21-5p. In internal validation, the area under the receiver operating characteristic curve (AUC) was 0.894 (95% confidence interval 0.788-0.975), with accuracy 0.844, sensitivity 0.840, and specificity 0.850. CONCLUSION: A five-marker tissue model discriminated benign from malignant breast lesions in internal validation. miR-205-5p/HMGB3 and miR-96-5p/FOXO1 were the leading inverse-expression candidates. External validation and functional confirmation are required before clinical use.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers