Frontiers in medical technology

HER2 amplification assessment in breast cancer in the HER2-SISH histopathological images using deep learning models.

Nitharsana C, Preethi Ramesh, Kaavya Ravichandran, Lohithaswin V, N Maheswari

School of Computer Science and Engineering, Vellore Institute of Technology, Chennai, India.

Computational

Key points

From the paper's conclusion
  • This work presents a systematic comparative evaluation of six deep learning architectures for multiclass HER2-SISH histopathology image classification across three diagnostic categories: Amplified, Non-Amplified, and ROI_Normal.

Abstract

Human Epidermal Growth Factor Receptor 2 (HER2) status is a critical determinant of breast cancer prognosis and therapeutic strategy. Silver in situ Hybridization (SISH) enables HER2 gene assessment under bright-field microscopy while preserving tissue morphology, rendering it a clinically favoured alternative to fluorescence-based methods. Nevertheless, manual SISH slide interpretation is subjective, time-intensive, and susceptible to inter-observer variability, necessitating robust automated computational solutions. This work presents a systematic comparative evaluation of six deep learning architectures for multiclass HER2-SISH histopathology image classification across three diagnostic categories: Amplified, Non-Amplified, and ROI_Normal. The evaluated architectures span convolutional neural networks (MobileNetV3-Large, DenseNet121), transformer-based models (ViT-Small, DeiT-Small), and novel hybrid CNN-Transformer frameworks (DenseNet121-ViT, DenseNet121-DeiT). All models were trained under five-fold stratified cross-validation with a split-before-augmentation protocol and evaluated on an independent held-out test set over both the original and an augmented version of the publicly available HER2-SISH40x dataset. On the original dataset, DenseNet121 achieved the highest test accuracy of 82.10% with a macro F1-score of 77.33%. After offline rotational augmentation of the training partition, DenseNet121 achieved the best performance with test accuracy of 85.09% and macro F1-score of 80.61%, with ViT-Small (84.47%) and DenseNet121-ViT (83.23%) following closely. Per-class analysis revealed that ROI_Normal was consistently classified with the highest accuracy, whereas Amplified versus Non-Amplified discrimination remained the principal challenge across all evaluated models.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers