Frontiers in Medicine

AI-assisted head-and-neck CTA interpretation improves interns' accuracy and diagnostic confidence: a prospective, crossover educational study with blinded reference-standard readers

Yawen Zheng, Hongyan Li, Lang Chen, Aihong Cao, Peng Du

Observational

Key points

From the paper's conclusion
  • Methods We conducted a prospective, within-subject crossover study with blinded reference-standard readers in which 30 first-year radiology interns read 160 head-and-neck CTA studies (100 abnormal, 60 normal) twice: once unassisted and once with a DL assistant (uAI Sphere, United Imaging Intelligence).

Abstract

Background Head-and-neck CT angiography (CTA) is a complex, multi-territory modality that is difficult for trainees to master. Deep-learning (DL) tools can automatically reconstruct and flag vascular disease, but whether they improve trainee performance in this specific setting—and on which lesion types—remains unclear. Methods We conducted a prospective, within-subject crossover study with blinded reference-standard readers in which 30 first-year radiology interns read 160 head-and-neck CTA studies (100 abnormal, 60 normal) twice: once unassisted and once with a DL assistant (uAI Sphere, United Imaging Intelligence). Readings were separated by a washout of at least 6 weeks, and reading order was randomized. Two senior radiologists (associate-professor rank or above) served as the reference standard, reading independently and then reaching consensus, blinded to intern and AI outputs. Primary endpoint was lesion-level sensitivity; secondary endpoints included study-level specificity, accuracy, AUC, confidence, reading time, and automation-bias events. Questionnaire and focus-group data explored trust calibration. Results With AI assistance, lesion-level sensitivity rose from 73.4% to 87.1% ( P < 0.001) and AUC from 0.81 to 0.90, while study-level specificity was unchanged (84.2% vs. 86.6%). Post-AI sensitivity was highest for intracranial aneurysms ≥3 mm (81.8% → 94.3%) and carotid stenosis ≥50% (71.7% → 89.1%), whereas the largest absolute gain was observed for dissection (55.6% → 74.1%), although its final sensitivity remained lower; the smallest gain was observed for rare/other disease (50.0% → 60.0%). Mean confidence rose from 2.85 to 3.78 and also rose on AI-wrong cases (2.31 → 3.55). Interns accepted 38% of AI false-positive marks and adopted AI under-calls in 32% of cases. Questionnaire and focus-group data showed anchoring on AI marks. Conclusion AI-assisted teaching of head-and-neck CTA should be stratified by lesion type and accompanied by explicit efforts to counter automation bias, rather than assumed to be uniformly helpful.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

AI-assisted head-and-neck CTA interpretation improves interns' accuracy and diagnostic confidence: a prospective, crossover educational study with blinded reference-standard readers — Science Skim