Frontiers in medicine

Evaluating laboratory-based AI across different liver disease spectra: reciprocal cross-cohort validation and comparison with FIB-4.

Raphael Augusto de Souza, Neilson Silveira de Souza, Helma Pinchemel Cotrim, Marcos Antônio Dórea Machado

Postgraduate Program in Medicine and Health, Faculty of Medicine of Bahia, Federal University of Bahia, Salvador, Bahia, Brazil. · Faculty of Medicine of Bahia, Federal University of Bahia, Salvador, Bahia, Brazil.

Observational · n=135

Key points

From the paper's conclusion
  • We evaluated laboratory-based AI models across two clinically distinct cohorts from a single institution and quantified their incremental performance over FIB-4.

Abstract

BACKGROUND: Artificial intelligence (AI) may improve non-invasive liver fibrosis assessment, but its performance across different liver disease spectra remains uncertain. We evaluated laboratory-based AI models across two clinically distinct cohorts from a single institution and quantified their incremental performance over FIB-4. METHODS: Two independent cohorts were analyzed: MASLD (n = 135) and heterogeneous chronic liver disease (HEPATO; n = 126). Models using six routine laboratory biomarkers were evaluated through reciprocal cross-cohort validation and pooled three-fold cross-validation. Discrimination was compared with FIB-4 using paired DeLong tests, and classifications at approximately 80% and 90% sensitivity using McNemar tests. Six eligible literature studies informed a random-effects meta-analysis, Bayesian evidence synthesis, and clinical operating-point simulations. RESULTS: Naive Bayes achieved AUCs of 0.76 in HEPATO and 0.75 in MASLD, compared with 0.68 and 0.72 for FIB-4, respectively; AUC differences were not statistically significant. In reciprocal cross-cohort operating-point analyses, AI showed numerically higher specificity than FIB-4 across all four validation scenarios, although achieved sensitivities differed between models, limiting direct specificity comparisons. Exploratory in-sample analyses suggested potential specificity gains requiring independent validation. The literature-only pooled ΔAUC was +0.074 (95% CI, +0.008 to +0.141; I2 = 82.3%). Bayesian updating yielded a posterior mean ΔAUC of +0.063 (95% CrI, approximately +0.0001 to +0.125), with an approximately 84.7% probability of ΔAUC >0.03. Simulated specificity gains were +10.9 and +10.2 percentage points at 80% and 90% sensitivity, respectively. CONCLUSIONS: Laboratory-based AI models demonstrated relatively consistent discrimination across two clinically distinct liver disease cohorts within a single-center setting. AI showed numerically higher specificity than FIB-4 across reciprocal cross-cohort operating-point analyses, although differences in achieved sensitivity preclude conclusions of superiority at matched operating points.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers