360° Micropulse laser trabeculoplasty versus medical therapy in open-angle glaucoma: a randomized trial of efficacy, safety, and anterior segment morphological changes
Peiling Xie, Na He, Xiaochun Li, Jialing He, Jing Bao
Key points
From the paper's conclusion- These findings support MLT as an effective, medication-sparing early intervention for open-angle glaucoma.
Abstract
Objective To evaluate the efficacy, safety, quality of life improvement, and morphological effects on the trabecular meshwork-Schlemm's canal outflow pathway of 360° MicroPulse Laser Trabeculoplasty (MLT) compared with guideline-escalated medical therapy in patients with open-angle glaucoma (OAG). Methods This prospective, randomized, parallel-group trial enrolled 90 patients with diverse OAG subtypes between February and April 2026. Participants were randomly assigned (1:1) to receive either 360° MLT (577 nm, 1000 mW, 15% duty cycle) or stepped medical therapy for 6 months. Primary outcomes included intraocular pressure (IOP) reduction, corneal endothelial cell density, and anterior segment optical coherence tomography (AS-OCT) quantification of Schlemm's canal diameter at baseline and month 3. Secondary outcomes comprised medication burden, Glaucoma Quality of Life-15 (GQL-15) scores, and adverse events. Results At 6 months, MLT achieved superior IOP reduction compared with medication (30.6% vs 21.8%; between-group difference 2.2 mmHg [95% CI: 1.1–3.3], P = 0.003). At month 3, AS-OCT demonstrated significant Schlemm's canal dilation with MLT (+37.2 μm, P < 0.001) but not medication. Corneal endothelium remained stable in both groups. MLT reduced medication burden by 61.1% (37.8% medication-free) versus no change with medication. GQL-15 scores improved more with MLT (5.8 vs. 1.1 points, P < 0.001). MLT had no serious adverse events; medication-related adverse events requiring intervention occurred only in the medication group (26.7% vs. 0%). Conclusions 360° MLT provides superior IOP control, reduced medication burden, and improved quality of life compared with medical therapy, and was associated with dilation of Schlemm's canal—a morphological change consistent with enhanced conventional aqueous outflow. These findings support MLT as an effective, medication-sparing early intervention for open-angle glaucoma. Clinical Trial Registration https://www.chictr.org.cn/showproj.html?proj=293191 , Number: ChiCTR2600117484; Registration Date: 20260126
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Corneal Endothelial Safety and Intraocular Pressure Outcomes of MicroPulse Laser Trabeculoplasty in Treatment-Naïve Glaucoma: A Six-Month Retrospective Study.Life (Basel, Switzerland) · 2026
- Selective Laser Trabeculoplasty in Open-Angle Glaucoma and Ocular Hypertension: A Narrative Review of Current Evidence.Journal of clinical medicine · 2026
- Safety and efficacy of micropulse transscleral laser therapy for glaucoma: a two-year follow-up.International journal of ophthalmology · 2026
- Mid to Long-Term Outcomes of Low-Energy Selective Laser Trabeculoplasty for Primary Open Angle Glaucoma.Journal of clinical medicine · 2026
- Direct selective Laser trabeculoplasty in the management of glaucoma: The first systematic review and meta-analysis.European journal of ophthalmology · 2026
- Dose-effectiveness Optimizing in Micropulse Transscleral Cyclophotocoagulation: A Cohort Study in Refractory Glaucoma.Ophthalmology. Glaucoma · 2026