Frontiers in Medicine

Silicone oil versus C3F8 gas in reoperative inverted ILM flap surgery for persistent myopic macular hole retinal detachment

Howard Wen-Haur Chao, Windsor Wen-Jin Chao, Hsiao-Ming Chao

Observational · n=18

Key points

From the paper's conclusion
  • This study compared the anatomical and functional outcomes of silicone oil (SiO) versus C3F8 tamponade in eyes with persistent MHRD following failed initial surgery.

Abstract

Introduction/objectives Myopic macular hole retinal detachment (MHRD) is a sight-threatening complication of high myopia that presents significant surgical challenges. The optimal tamponade agent when using an inverted internal limiting membrane (ILM) flap for persistent MHRD remains unclear. This study compared the anatomical and functional outcomes of silicone oil (SiO) versus C3F8 tamponade in eyes with persistent MHRD following failed initial surgery. Methods This retrospective study included 36 highly myopic eyes with persistent MHRD after failed initial pars plana vitrectomy (PPV) with ILM peeling, drainage retinotomy and SF6 tamponade. All eyes underwent repeat PPV with an inverted ILM flap and either SiO ( n = 18) or C3F8 ( n = 18) tamponade. Macular hole (MH) closure, SRF resolution, best-corrected visual acuity (BCVA) and outer retinal microstructural recovery were assessed over a mean follow-up of 46.45 months using spectral-domain optical coherence tomography. BCVA comparisons were adjusted for pre-flap BCVA. Results Any MH closure was higher with SiO than C3F8 (94.4% vs. 55.6%; P = 0.018). Complete closure (77.8% vs. 50.0%), absence of postoperative subretinal fluid (94.4% vs. 66.7%; P = 0.088) and complete ellipsoid zone (EZ) restoration (44.4% vs. 11.1%) were numerically more frequent with SiO but did not reach significance. Any restoration of the external limiting membrane (ELM) (77.8% vs. 22.2%; P = 0.002) and EZ (83.3% vs. 38.9%; P = 0.015) was greater with SiO. Mean BCVA improved from 1.10 to 0.56 logMAR with SiO and from 1.42 to 1.31 logMAR with C3F8. After adjustment for pre-flap BCVA, BCVA was significantly better with SiO at all time points, by approximately 0.4 to 0.5 logMAR from two months onward. Conclusions In persistent MHRD following failed initial surgery, inverted ILM flap surgery with SiO was associated with higher rates of MH closure, greater outer retinal recovery and better visual acuity than C3F8. These findings suggest that SiO may be a useful tamponade option in this challenging group, pending confirmation in prospective studies.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers