Frontiers in medicine

Guide plate technology improves traditional fluoroscopy on the fixation of AO/OTA 33-C distal femur fractures with integrated nail-plate double distalis entry technique: a retrospective comparative study.

Yongde Wu, Bo Chen

Department of Orthopedics, Yichang Central People's Hospital, The People's Hospital of China Three Gorges University, Yi Chang, Hubei, China.

Observational · n=2,100

Key points

From the paper's conclusion
  • NPC-GD can facilitate fracture healing and achieve satisfactory repair of knee function, which is a preferred method of AO/OTA 33-C distal femoral fracture internal fixation.

Abstract

INTRODUCTION: NPC (nail-plate construct) has become the surgical mainstay for AO/OTA 33-C-type femoral fracture. Two NPC (nail-plate construct) techniques have been developed: a dedicated surgical guide device-assisted technique (NPC-GD) which adjusts conventional intraoperative fluoroscopy to lead to more accurate reduction of fractures and safer implant placement than ordinary fluoroscopy-guided technique, and a regular fluoroscopy-guided technique (NPC-GF). Aim: Comparison of surgical outcomes, quality of life and functional recovery in patients with AO/OTA 33-C-type femoral fractures using either NPC-GD or NPC-GF. METHODS: A retrospective comparative analysis was conducted among 161 cases enrolled from Jan. 2020 to Jan. 2025 including 86 cases in NPC-GD group and 75 cases in NPC-GF group. Operative time, operation blood loss, fluoroscopy frequency, rate of malunion, healing time, weight-bearing time, knee range of motion and HSS knee score were statistically compared. Outcome evaluations were all performed in a blinded fashion. RESULTS: This final analysis included 161 patients: 86 in the NPC-GD group and 75 in the NPC-GF group. NPC-GD group had a shorter operative time (P = 0.006), intraoperative (P = 0.004) and postoperative (P = 0.003) blood loss, fewer numbers of intraoperative fluoroscopic images (P = 0.034), shorter time to radiographic fracture union (P = 0.037), earlier onset of walking at final follow-up (P = 0.001), earlier achievement of full weight-bearing at final follow-up (P = 0.009), greater final knee range of motion (P = 0.009), better HSS knee scores (P = 0.002). CONCLUSIONS: NPC-GD is the optimized fluoroscopy technique; it reduces the surgical damage and excess irradiation. NPC-GD can facilitate fracture healing and achieve satisfactory repair of knee function, which is a preferred method of AO/OTA 33-C distal femoral fracture internal fixation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers