Ventilator care bundles in adult ICUs: a systematic review and meta-analysis of ventilator-associated pneumonia risk and incidence density.
Mingfang Qian, Yan Lan
Department of Critical Care Medicine (Zhijiang Campus), Tongde Hospital of Zhejiang Province, Hangzhou, China.
Key points
From the paper's conclusion- Systematic Review Registration PROSPERO (CRD420261484358).
Abstract
BACKGROUND: Ventilator care bundles are used to prevent ventilator-associated pneumonia (VAP), but differences in outcome denominators and study design complicate interpretation. We examined patient-level VAP risk and ventilator-time incidence density separately. METHODS: PubMed/MEDLINE, Embase, CENTRAL, and Web of Science were searched from inception on 11 August 2026. Eligible bundles contained at least three clinical practices for adults receiving invasive mechanical ventilation in ICUs. Nonconcurrent before-after comparisons were pooled separately for VAP risk ratios (RRs) and incidence rate ratios (IRRs). Comparisons with unclear timing, randomized results, and segmented interrupted time-series results were presented separately. Random-effects models used restricted maximum likelihood and Knapp-Hartung intervals, with modified Knapp-Hartung sensitivity analyses. ROBINS-I and GRADE assessed bias and certainty. RESULTS: Twenty-three non-randomized study families contributed to the primary meta-analyses; 22 contributed VAP data. Bundle implementation was associated with lower VAP risk (14 studies; n = 5,905; RR 0.62, 95% CI 0.51-0.76; I2 = 9.0%; prediction interval 0.47-0.82). The pooled incidence rate ratio was 0.55 (12 studies; 95% CI 0.41-0.73; I2 = 79.9%), but the prediction interval included the null (0.25-1.22). ICU length of stay (3 studies; MD -2.53 days, 95% CI -7.59 to 2.53) and mechanical ventilation duration (2 studies; MD -3.64 days, 95% CI -13.96 to 6.69) remained uncertain. All pooled estimates were at serious risk of bias. Certainty was low for VAP risk and very low for the other pooled outcomes. CONCLUSIONS: Nonconcurrent comparisons associated bundle implementation with lower reported VAP risk, with low certainty. Incidence-density associations varied across settings, and evidence for ICU length of stay and ventilation duration was very uncertain. Evaluations with independent concurrent controls, stable surveillance, and adherence monitoring are needed. SYSTEMATIC REVIEW REGISTRATION: PROSPERO (CRD420261484358).
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evidence-Based Practices to Prevent Ventilator-Associated Pneumonia in an Intensive Care Unit in BangladeshHealthcare · 2025
- Incidence of ventilator-associated pneumonia in neonatal intensive care units: a systematic review and meta-analysis.Paediatric respiratory reviews · 2026
- Comparative analysis of ventilator-associated pneumonia and ventilator-associated event surveillance systems: a retrospective observational study.Journal of Korean biological nursing science · 2026
- Primary preventive interventions to reduce ventilator-associated pneumonia in neonatal intensive care units: a meta-analysis.Pediatric research · 2026
- A Comparative Analysis of Intensive Care Unit Nurses' Knowledge and Practice Regarding Ventilator-Associated Pneumonia Prevention in Government and Private Hospitals.SAGE open nursing · 2026
- Essential aspects of the prevention of ventilator-associated pneumonia: A State-of-the-Art Review.Intensive & critical care nursing · 2026