Artificial intelligence for ultrasound-based differentiation of soft tissue liposarcoma from benign masses.
YuKun Deng, Chengjia Qu, Yi Cao, Guoyang Yu, Jingmiao Yu, Jie Yang, Wen Guo, Dandan Wang,
Department of Medical Ultrasonics, Beijing Jishuitan Hospital Affiliated to Capital Medical University, National Center for Orthopedics, Beijing, China. · Department of Vascular Surgery, Beijing Jishuitan Hospital Affiliated to Capital Medical University, National Center for Orthopedics, Beijing, China.
Key points
From the paper's conclusion- Conclusions A two-stage deep learning model using ultrasound images showed preliminary potential for differentiating liposarcoma from benign masses in this single-center cohort.
Abstract
BACKGROUND: Accurate preoperative differentiation of liposarcoma from benign masses on ultrasound remains challenging and operator-dependent. We aimed to develop and validate a deep learning-based model to assist in distinguishing liposarcoma from benign masses. METHODS: In this retrospective single-center study, we collected B-mode ultrasound examinations from patients with soft tissue masses between March 2015 and March 2022 at Beijing Jishuitan Hospital affiliated to Capital Medical University. A two-stage deep convolutional neural network was developed: a U-Net model segmented tumor regions, followed by a ResNet50 classifier for tumor type prediction. The cohort (n = 317) was split at the patient level into a development set (n = 222) and an internal test set (n = 95). Model performance was compared with 4 radiologists in the internal test set. RESULTS: Among 317 cases, 191 were benign masses and 126 were liposarcomas. In the internal test set, the AI model achieved an AUC of 0.97 (95% CI 0.92-1.00), an accuracy of 0.97 (95% CI 0.93-1.00), a sensitivity of 0.96 (95% CI 0.86-1.00), and a specificity of 0.97 (95% CI 0.93-1.00). AI achieved significantly higher accuracy than both residents after Holm adjustment (adjusted P = 0.0156 and 0.0352, respectively). Differences between AI and either specialist were not statistically significant (both adjusted P = 1.0000). CONCLUSIONS: A two-stage deep learning model using ultrasound images showed preliminary potential for differentiating liposarcoma from benign masses in this single-center cohort. External validation is required before clinical use.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Externally validated MRI radiomics machine learning models for differentiating between myxoid liposarcoma and myxoma.Skeletal radiology · 2026
- Development and External Testing of an Interpretable MRI-Based Machine Learning Model for Differentiating Endometrial Stromal Sarcoma from Cellular Leiomyoma.Journal of imaging informatics in medicine · 2026
- Objective classification of masseter muscle and deep inferior tendon morphology: A comparative performance analysis of machine learning algorithms.Cranio : the journal of craniomandibular practice · 2026
- Development and Validation of a Convolutional Neural Network Framework Based on Ultrasound Imaging for Multi-Classification of Superficial Soft Tissue Masses.Academic radiology · 2026
- Performance of deep learning-based segmentation of soft tissue sarcoma by MRI sequence, tumor type and locationSkeletal Radiology · 2026
- Integrating nnU ‐Net Segmentation and Clinical–Radiomics for Multicenter MRI ‐Based Assessment of Soft Tissue Sarcoma Grade and Ki‐67 ExpressionJournal of Magnetic Resonance Imaging · 2026