Frontiers in medicine

Failure mode and effects analysis-guided digital redesign of the intraoperative frozen-section specimen pathway: a before-and-after service improvement study.

Juan Liu, Xu Li, Huating Zhang, Shuwei Wang, Xiaoyang Zhou

Department of Anesthesiology and Perioperative Medicine, Second Division, Central Campus, Shandong First Medical University Affiliated Provincial Hospital, Jinan, China.

Observational

Key points

From the paper's conclusion
  • Aim To evaluate an FMEA-guided digital redesign program incorporating a dedicated frozen-section pathway, standardized verification procedures, barcode-based handover, repeat-submission registration, targeted training, and real-time workflow monitoring.

Abstract

BACKGROUND: Intraoperative frozen-section specimen pathways cross professional and departmental boundaries and are vulnerable to identification, handover, and transport failures. A failure mode and effects analysis (FMEA)-guided closed-loop workflow redesign may provide a structured approach to improving specimen traceability and reducing preventable process failures. AIM: To evaluate an FMEA-guided digital redesign program incorporating a dedicated frozen-section pathway, standardized verification procedures, barcode-based handover, repeat-submission registration, targeted training, and real-time workflow monitoring. METHODS: This single-center, non-randomized before-and-after study was conducted at a tertiary teaching hospital in eastern China. All registered frozen-section specimens from October-December 2025 (pre-implementation; n = 238) and January-March 2026 (post-implementation; n = 247) were included. The intervention included a dedicated frozen-section pathway, standardized verification procedures, a single-record register for repeat submissions, barcode-based handover, role-specific training, and real-time monitoring of workflow deviations. RESULTS: Transport timeliness improved from 80.7% (192/238) before implementation to 98.4% (243/247) after implementation, representing an absolute increase of 17.7 percentage points (95% CI 12.5-23.0; risk ratio 1.22, 95% CI 1.14-1.30; p < 0.001). Handover-record accuracy improved from 75.2% (179/238) to 99.2% (245/247), representing an absolute increase of 24.0 percentage points (95% CI 18.4-29.6; risk ratio 1.32, 95% CI 1.23-1.42; p < 0.001). Staff-reported satisfaction increased descriptively from 71.0% (44/62) to 95.2% (59/62).

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers