Multiparametric MRI-based radiomics for differentiating HER2-negative, HER2-low, and HER2-positive breast cancer.
Lulu Gai, Shubin Luo, Yudong Yan, Wenzheng Lyu, Xingyu Zhao, Haiming Cao, Kaifeng Wang, Yunpeng Zhou,
Department of Medical Imaging, Shengli Oilfield Central Hospital, Dongying, China. · Shandong Second Medical University, Weifang, China.
Key points
From the paper's conclusion- Training-set model selection followed by independent test-set evaluation identified the strongest discrimination between HER2-negative and HER2-positive tumors. Performance was less reliable when HER2-low tumors were involved, particularly for HER2-negative versus HER2-low classification. These findings are exploratory and require independent multicenter validation.
Abstract
BACKGROUND: Breast cancer stratification increasingly extends beyond conventional TNM staging and binary human epidermal growth factor receptor 2 (HER2) classification. This shift is driven in part by the therapeutic relevance of HER2-low disease. We investigated whether multiparametric MRI-based radiomics could support pairwise discrimination among HER2-negative, HER2-low, and HER2-positive breast cancers. METHODS: This retrospective single-center study included 157 patients who underwent breast MRI on two 3.0-T scanners. Radiomic features were extracted from T2-weighted, contrast-enhanced T1-weighted, and subtraction T1-weighted images. Seven classifiers were compared after a stratified 8:2 training-test split. Model development, five-fold cross-validation, and model selection were confined to the training set, and the selected logistic regression model was evaluated on the untouched test set. RESULTS: Logistic regression had the highest mean training AUC across the three pairwise tasks (0.778) and was selected as the common final classifier. Test-set AUCs were 0.922 (95% CI, 0.750-1.000) for HER2-negative versus HER2-positive, 0.756 (95% CI, 0.529-0.938) for HER2-low versus HER2-positive, and 0.705 (95% CI, 0.493-0.893) for HER2-negative versus HER2-low classification. CONCLUSIONS: Training-set model selection followed by independent test-set evaluation identified the strongest discrimination between HER2-negative and HER2-positive tumors. Performance was less reliable when HER2-low tumors were involved, particularly for HER2-negative versus HER2-low classification. These findings are exploratory and require independent multicenter validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Preoperative prediction of HER2 status in breast cancer using multiparametric MRI deep learning and clinical features.Magnetic resonance imaging · 2026
- Integrating intratumoral and peritumoral radiomics with deep transfer learning from multiparametric MRI for preoperative prediction of HER2 status in breast cancer: a multicenter study.Frontiers in oncology · 2026
- Multiparametric MRI and artificial intelligence for non-invasive HER2 assessment in breast cancer: a comprehensive review.Frontiers in medicine · 2026
- Whole-phase DCE-MRI radiomics for differentiating benign and malignant BI-RADS 4 breast lesions: a comparative machine learning study.BMC medical imaging · 2026
- Mammography-based deep learning radiomics for predicting HER2 expression in breast cancer: a dual-center study with focus on HER2-low statusBMC Medical Imaging · 2026
- Intratumoral heterogeneity derived from synthetic MRI for characterization of HER2 subtypes in breast cancer.Frontiers in oncology · 2026