Deep learning-based multiclass classification for the diagnosis of hand arthritis on digital radiography: a multicenter study.
Chao Deng, Dan Yan, Cong Tang, Xuemei Deng, Chuanyu Li, Xikui Chen, Lihua Deng, Zhe Wu
Department of Radiology, The First People's Hospital of Neijiang, Neijiang, Sichuan, China. · Department of Radiology, Suining Central Hospital, Suining, Sichuan, China.
Key points
From the paper's conclusion- The transformer-based model showed strong internal performance and retained useful discriminative ability in an independent external cohort; however, the reduction in external accuracy and macro-F1 indicated limited cross-center transferability. These findings support the feasibility of the proposed approach while emphasizing the need for broader prospective validation and reader-performance studies before clinical deployment.
Abstract
BACKGROUND: To develop and independently validate a deep learning framework for multiclass differentiation of osteoarthritis (OA), rheumatoid arthritis (RA), gouty arthritis (GA), and normal controls on hand digital radiographs. METHODS: This retrospective multicenter study included 1,179 hand radiographs from 520 participants at four institutions. A three-center development cohort comprised 1,001 radiographs from 431 participants and was evaluated using patient-level stratified five-fold cross-validation. ResNet50, ResNet101, DenseNet121, and Vision Transformer (ViT) were trained using an identical pipeline. The internally best model, ViT, was retrained on the complete development cohort and evaluated once on an independent fourth-center cohort of 178 radiographs from 89 participants that was held out from training and model selection. RESULTS: ViT achieved the numerically highest internal performance, with an accuracy of 0.937 ± 0.029 and a macro-F1 score of 0.937 ± 0.029. On independent external validation, ViT correctly classified 133 of 178 radiographs, with accuracy of 0.747, macro-precision of 0.756, macro-recall of 0.747, macro-specificity of 0.916, macro-F1 of 0.744, and macro-AUC of 0.917. External class-wise AUCs were 0.948 for RA, 0.873 for OA, 0.888 for GA, and 0.959 for normal controls. CONCLUSION: The transformer-based model showed strong internal performance and retained useful discriminative ability in an independent external cohort; however, the reduction in external accuracy and macro-F1 indicated limited cross-center transferability. These findings support the feasibility of the proposed approach while emphasizing the need for broader prospective validation and reader-performance studies before clinical deployment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- DIFFERENTIAL DIAGNOSIS OF HAND ARTHRITIS ON RADIOGRAPHS USING DEEP LEARNING.Osteoarthritis imaging · 2026
- Comparison of the Performances of Deep Learning Methods in Kellgren-Lawrence Classification of Knee Osteoarthritis: A Multicenter Study.Journal of imaging informatics in medicine · 2026
- auto scoRA : Deep Learning to Automate Sharp/van der Heijde Scoring of Radiographic Damage in Rheumatoid ArthritisArthritis & Rheumatology · 2026
- Densenet201+ with multi-scale attention and deep feature engineering for automated Kellgren–Lawrence grading of knee osteoarthritisPeerJ Computer Science · 2025
- Performance Evaluation of Deep Learning Applications in Calcaneal Fracture Diagnosis Using Separate Radiographic Views: A Comparison of CNN and Vision Transformer Architectures.Diagnostics (Basel, Switzerland) · 2026
- How Robust Are CNNs and Vision Transformers for Alzheimer's MRI Classification Across Datasets?arXiv · 2026