Inadequate neuraxial anesthesia during cesarean delivery: incidence and predictors in a large retrospective contemporary cohort.
Orhun Demir, Omer Zuhtu Yondem, Baris Ecevit Yuksel
Department of Anesthesiology, Faculty of Medicine, Lokman Hekim University, Ankara, Türkiye.
Key points
From the paper's conclusion- This study aimed to determine the incidence of inadequate spinal anesthesia during cesarean delivery and to identify patient- and procedure-related factors associated with block inadequacy.
Abstract
OBJECTIVE: Spinal anesthesia is the preferred anesthetic technique for cesarean delivery because of its favorable maternal and neonatal safety profile. Despite its widespread use, inadequate neuraxial anesthesia remains an important clinical problem that may result in intraoperative pain, supplemental pain relief, or conversion to general anesthesia. Previous studies have shown inconsistent incidence rates and unreliable predictors of failed spinal anesthesia. This study aimed to determine the incidence of inadequate spinal anesthesia during cesarean delivery and to identify patient- and procedure-related factors associated with block inadequacy. METHODS: This retrospective cohort study included all adult patients who underwent cesarean delivery under planned spinal anesthesia at a tertiary university hospital between January 2020 and January 2026. Inadequate spinal anesthesia was defined as the combination of partial and total failure of spinal block. Demographic, obstetric, anesthetic, and surgical variables were evaluated. Multivariable logistic regression analysis was performed to identify independent predictors of inadequate spinal anesthesia. RESULTS: A total of 3,382 cesarean deliveries performed under spinal anesthesia were analyzed. Adequate spinal anesthesia was achieved in 3,216 patients (95.1%). Inadequate spinal anesthesia occurred in 166 patients (4.9%), including 135 partial failures (4.0%) and 31 total failures (0.9%). Increasing age and higher educational level were associated with lower odds of inadequate spinal anesthesia, whereas postpartum sterilization and surgical adhesions were independently associated with higher odds of inadequate spinal anesthesia. CONCLUSIONS: Although spinal anesthesia provided effective surgical anesthesia in the vast majority of cesarean deliveries, inadequate neuraxial block remained clinically relevant. Both patient-related and surgical factors were associated with an increased risk of block inadequacy. Identification of high-risk patients may facilitate individualized anesthetic planning and improve maternal intraoperative experience.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Incidence of Pain during Cesarean Delivery with Neuraxial Anesthesia: An International, Prospective Cohort StudyAnesthesiology · 2025
- The effect of maternal preoperative demographics on the cephalad spread of spinal anesthesia for cesarean delivery – a retrospective analysis of cases anesthetized with high dose of hyperbaric bupivacaineBMC Pregnancy and Childbirth · 2026
- Intrathecal bupivacaine versus bupivacaine plus fentanyl for anaesthesia for Caesarean delivery: a randomised double-blind noninferiority trialBritish Journal of Anaesthesia · 2025
- Association between prior epidural labour analgesia and increased incidence of hypotension after spinal anaesthesia for caesarean section: A retrospective propensity score-matched cohort study.Anaesthesia and intensive care · 2026
- Women’s reported experience of conversion to general anesthesia for cesarean delivery with inadequate neuraxial anesthesia: a qualitative prospective multicenter Danish studyInternational Journal of Obstetric Anesthesia · 2026
- Women's experience of pain during cesarean delivery due to inadequate neuraxial anesthesia without conversion to general anesthesia: a qualitative study.International journal of obstetric anesthesia · 2026