Prognostic value of 48-h reassessment of a laboratory-derived frailty index in ICU patients with sepsis: model development in MIMIC-IV and external transport evaluation.

Ming He, Yuxuan Zhang, Jiujia Xiao, Mengjiao Yang, Yi Wen, Dan Huang

Department of Critical Care Medicine, The First Affiliated Hospital of Chengdu Medical College, Chengdu, Sichuan, China.

Observational · n=6,153

Key points

From the paper's conclusion
  • FI-lab-23 reassessed at 24-48 h provided updated prognostic information for 28-day mortality in ICU patients with sepsis. The frozen MIMIC-IV model showed encouraging but imprecise performance in a selected single-center complete-case cohort. These findings constitute supportive transport evidence rather than definitive external validation, and larger multicenter studies are required before clinical implementation.

Abstract

BACKGROUND: Static laboratory-derived frailty index (FI-lab) measures have been associated with adverse outcomes in sepsis, but the value of reassessing acute multisystem laboratory abnormality burden after initial resuscitation and transporting a prespecified model to a new clinical setting remains uncertain. METHODS: We conducted a retrospective 48-h landmark study using MIMIC-IV for model development and an independent single-center ICU sepsis cohort from January 2020 to December 2025 for supportive single-center transport evaluation. FI-lab-23 was calculated from 23 routine laboratory variables using prespecified thresholds, with at least 17 components required, and was interpreted as an acute laboratory deficit-accumulation index rather than chronic frailty. The primary extended model added FI-lab-23 measured at 24-48 h to clinical variables; the strict secondary model additionally included lactate clearance. Fixed-horizon logistic regression predicted 28-day mortality among patients alive and remaining in the ICU at 48 h. MIMIC-IV coefficients were frozen and applied without refitting to the local cohort. Performance was assessed by discrimination, Brier score, calibration, and exploratory decision-curve analysis. Baseline/change parameterizations were treated as secondary specification analyses; sensitivity analyses addressed testing intensity, component completeness, and a fixed 10-component common-core FI. RESULTS: The primary MIMIC-IV development cohort included 6,153 patients with 1,594 deaths. Each 0.05 increase in 24-48 h FI-lab-23 was associated with higher 28-day mortality (OR: 1.178, 95% CI: 1.149-1.207). Optimism-corrected AUC was 0.710. Of 722 local landmark-eligible patients, 328 met the primary complete-case requirements (85 deaths). In this selected cohort, the frozen model achieved an AUC of 0.774, Brier score of 0.160, calibration intercept of 0.109, calibration slope of 1.273, and observed-to-expected ratio of 1.074. Baseline FI-lab did not improve fit after the 48-h level was known, and baseline-by-change interactions were not significant. The direction of association was preserved across sensitivity analyses, although effect magnitude varied with component-completeness criteria. CONCLUSIONS: FI-lab-23 reassessed at 24-48 h provided updated prognostic information for 28-day mortality in ICU patients with sepsis. The frozen MIMIC-IV model showed encouraging but imprecise performance in a selected single-center complete-case cohort. These findings constitute supportive transport evidence rather than definitive external validation, and larger multicenter studies are required before clinical implementation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers