Airway hydration homeostasis in artificial airways: from mucus biophysics to monitoring and humidification strategies in critical care: a narrative review.
Haishao Chen, Xunbin Qiu, Kaisheng Ye, Qun Wang
Department of Anesthesiology, Binhaiwan Central Hospital of Dongguan, Dongguan, Guangdong, China. · Department of Anesthesiology, The First Affiliated Hospital of Jinan University, Guangzhou, Guangdong Province, China.
Key points
From the paper's conclusion- Future studies should determine whether integrating patient characteristics, secretion properties, ventilatory conditions, and device performance can support more individualized humidification strategies.
Abstract
Artificial airway placement bypasses the physiological warming and humidifying functions of the upper airway. This produces a distal shift of the isothermic saturation boundary and exposes the tracheobronchial mucosa to additional evaporative stress. When inspired gas is inadequately conditioned, the resulting evaporative stress can deplete airway surface liquid, concentrate mucus, impair mucociliary clearance, and promote secretion retention and mucus plugging. Airway hydration imbalance is not simply a problem of insufficient water delivery. Rather, it reflects a dynamic interaction among gas thermodynamics, epithelial ion transport, mucin network organization, inflammatory burden, secretion biophysics, and ventilator-patient conditions. Current humidification strategies, mainly heated humidifiers and heat-and-moisture exchangers, provide essential support during invasive and non-invasive ventilation. However, their performance is often constrained by open-loop operation, device-related limitations, and heterogeneous patient requirements. This review summarizes the physiological basis of airway hydration, the mechanisms by which artificial airways disturb hydration homeostasis, clinical assessment approaches, and current humidification strategies. It also discusses newer approaches, including ventilator waveform-derived indices, microrheological assays, artificial cilia sensors, microfluidic platforms, and closed-loop humidification frameworks. Future studies should determine whether integrating patient characteristics, secretion properties, ventilatory conditions, and device performance can support more individualized humidification strategies. Technologies that remain at the model or prototype stage should be interpreted cautiously.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The inspired-expired temperature gradient: a candidate bedside readout of airway gas-conditioning stress during invasive ventilation.Journal of applied physiology (Bethesda, Md. : 1985) · 2026
- Pulmonary hydrogels for respiratory disease: route-specific materials design, dynamic barriers, applications, and translationFrontiers in Materials · 2026
- Hydrogels in Airway Devices and Tracheal Repair: Clinical Requirements, Patient-Specific Manufacturing, and Translational Testing.Small methods · 2026
- Airway Mucosal Defense: Mucins, Innate Immunity, and Contemporary Mucoactive StrategiesBiomedicines · 2026
- Computational Analysis of Unsteady Airway Flow Physics During Airway Pressure Release Ventilation.Journal of biomechanical engineering · 2026
- Design and Architecture of Airmod: An Active Noise Cancellation and Deep Learning System for Real-Time Respiratory Rate Estimation from Tracheal SoundsarXiv · 2026