Frontiers in medicine

A deep learning model for preoperative differentiation of uterine adenomyoma and uterine leiomyoma on transvaginal ultrasound.

Peilin Sheng, Jianmin Wang, Qian Lu, Zicheng Zeng, Xiaobo Lai, Liming Yang, Jianqing Wang

School of Medical Technology and Information Engineering, Zhejiang Chinese Medical University, Hangzhou, China. · Key Laboratory of Reproductive Dysfunction Management of Zhejiang Province, Department of Obstetrics and Gynecology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, China.

Computational · n=98

Key points

From the paper's conclusion
  • Introduction To develop and validate a deep learning model for the preoperative differentiation of uterine adenomyoma and uterine leiomyoma on transvaginal ultrasound.

Abstract

INTRODUCTION: To develop and validate a deep learning model for the preoperative differentiation of uterine adenomyoma and uterine leiomyoma on transvaginal ultrasound. METHODS: This retrospective study included 207 transvaginal ultrasound images from 98 patients between January 2020 and January 2025, split at the patient level into a training set (68 patients, 140 images) and an independent test set (30 patients, 67 images). A comparative framework was established: (1) radiomics models; (2) standard deep learning models; and (3) the proposed ResNet-50 model enhanced with the channel-aware feature modulation module. Three gynecologic ultrasonographers independently reviewed the test images for comparison with model performance. Model performance was evaluated using accuracy, precision, sensitivity, specificity, F1-score, and the area under the receiver operating characteristic curve (AUC). Exploratory explainability analyses used SHAP for the best-performing radiomics model and Grad-CAM for the proposed model. RESULTS: On the patient-level test set, the proposed model showed favorable numerical performance among the evaluated models, with an accuracy of 0.833, F1-score of 0.800, and AUC of 0.855 (95% CI: 0.693-0.982). The best-performing radiomics model, Logistic Regression, achieved a patient-level accuracy of 0.667 and AUC of 0.814 (95% CI: 0.630-0.962). The proposed model showed numerically higher accuracy than the three readers. SHAP summarized the contributions of radiomic features, whereas Grad-CAM visualized image regions associated with model predictions. CONCLUSION: The proposed model showed promising internal test performance for differentiating uterine adenomyoma from uterine leiomyoma on transvaginal ultrasound and may serve as a potential decision-support approach, warranting external and prospective validation.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers