Case Report: Electrical impedance tomography-guided ultra-protective lung ventilation during veno-venous extracorporeal membrane oxygenation support for fat embolism syndrome complicated by severe acute respiratory distress syndrome.
Jiahui Meng, Meng Wu, Jianhua Hu, Yaxin Ning, Danqiong Wang
Department of Critical Care Medicine, The Quzhou Affiliated Hospital of Wenzhou Medical University, Quzhou People's Hospital, Quzhou, Zhejiang, China.
Key points
From the paper's conclusion- Bedside EIT enables dynamic assessment of pulmonary status and may assist in optimizing ventilator settings, providing a useful reference for the management of FES complicated by severe ARDS.
Abstract
BACKGROUND: Fat embolism syndrome (FES) is a rare complication of severe multiple trauma. Electrical impedance tomography (EIT) is a noninvasive, real-time, bedside tool for monitoring regional pulmonary ventilation. Veno-venous extracorporeal membrane oxygenation (VV-ECMO) may improve outcomes in critically ill patients in whom conventional mechanical ventilation fails. Ultra-protective lung ventilation strategy (ULPVS) uses very low tidal volumes to markedly reduce lung stress and mitigate ventilator-induced lung injury (VILI). CASE PRESENTATION: In June 2025, a 57-year-old woman was admitted to the Department of Orthopedics with a femoral shaft fracture following a motor vehicle accident. Severe respiratory distress developed postoperatively, and she was urgently transferred to the ICU. Based on laboratory findings, chest CT findings, and Oil Red O staining of bronchoalveolar lavage fluid (BALF), FES complicated by severe acute respiratory distress syndrome (ARDS) was considered. In addition to conventional treatment, VV-ECMO was initiated to provide gas-exchange support. An ULPVS was implemented during the early phase of ventilation to reduce the risk of VILI, and EIT was used to guide ventilatory management and titration of the optimal Positive end-expiratory pressure (PEEP) Following these interventions, static lung compliance increased from 46 mL/cmH2O to 67.1 mL/cmH2O. VV-ECMO support lasted 62 h, and the total duration of mechanical ventilation was 113 h. After stabilization, the patient was transferred back to the Department of Orthopedics and was ultimately discharged in good condition. CONCLUSION: Bedside EIT enables dynamic assessment of pulmonary status and may assist in optimizing ventilator settings, providing a useful reference for the management of FES complicated by severe ARDS.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Electrical impedance tomography-guided individualized ventilation strategy in patients with trauma-related and postoperative acute respiratory distress syndrome.PloS one · 2026
- Regional ventilation at EIT-guided PEEP and mortality in severe ARDS: a prospective observational study.BMC pulmonary medicine · 2026
- Accuracy of electrical impedance tomography to detect perfusion defects in pulmonary embolismCritical Care · 2026
- The impact of PEEP-guided electrical impedance tomography on oxygenation and respiratory mechanics in moderate-to-severe ARDS: a randomized controlled trialScientific Reports · 2025
- A multicenter comparative study of saline contrast electrical impedance tomography method versus CTPA for the diagnosis of acute pulmonary embolism: a trial protocol.BMC medical imaging · 2026
- Non-Ultrasound-Guided Versus Ultrasound-Guided Femoral Venous Puncture in the Interventional Pulmonary Embolism Era: Does Ultrasound Guidance Improve Safety and Feasibility?Reviews in cardiovascular medicine · 2026