Frontiers in medicine

Donor-size-normalized tidal volume and early peak airway pressure-derived pressure burden after lung transplantation: an exploratory single-center cohort study.

Tao Wang, Yang Zhou, Xue Li, Jing Hu, Ding Huang, Weidong Wang, Rui Li, Junrong Ding

Department of Thoracic Surgery, Shanghai Pulmonary Hospital, Tongji University School of Medicine, Shanghai, China. · Department of Nursing, Shanghai Pulmonary Hospital, Tongji University School of Medicine, Shanghai, China.

Observational

Key points

From the paper's conclusion
  • Among 85 adult lung transplant recipients in the primary complete-case analysis, higher T0 dPBW-normalized tidal volume was associated with lower T0 peak pressure difference after enhanced adjustment (β = -0.531, 95% CI -1.031 to -0.032; P = 0.0376). Secondary analyses of dynamic compliance showed an association with higher time-matched dynamic compliance. In contrast, dPBW-normalized tidal volume did not show significant associations with severe primary graft dysfunction, liberation from invasive mechanical ventilation within 28 days, or 30-day mortality after enhanced adjustment.

Abstract

INTRODUCTION: After lung transplantation, the ventilated parenchyma is the donor lung rather than the recipient's native lung. Normalizing tidal volume to donor-predicted body weight (dPBW) indexes delivered ventilation to estimated graft size. METHODS: We conducted a retrospective single-center cohort study to evaluate whether dPBW-normalized tidal volume at intensive care unit admission after transplantation (T0) was associated with time-matched peak pressure difference under clinician-selected ventilation. Peak pressure difference was defined as peak airway pressure minus positive end-expiratory pressure and served as a peak airway pressure-derived pressure-burden metric rather than standard driving pressure. RESULTS: Among 85 adult lung transplant recipients in the primary complete-case analysis, higher T0 dPBW-normalized tidal volume was associated with lower T0 peak pressure difference after enhanced adjustment (β = -0.531, 95% CI -1.031 to -0.032; P = 0.0376). Secondary analyses of dynamic compliance showed an association with higher time-matched dynamic compliance. In contrast, dPBW-normalized tidal volume did not show significant associations with severe primary graft dysfunction, liberation from invasive mechanical ventilation within 28 days, or 30-day mortality after enhanced adjustment. DISCUSSION: These exploratory findings describe associations between dPBW-normalized tidal volume and early peak airway pressure-derived burden under clinician-selected ventilation, but they do not establish a physiologic effect or support changes in ventilatory management. Prospective validation with protocolized ventilation and plateau-pressure measurements is required.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers