Serum biomarkers for the prediction and diagnosis of preeclampsia: a systematic meta-analysis of diagnostic accuracy.
Xiang Li
Department of Gynecology and Obstetrics, Tianjin Medical University General Hospital, Tianjin, China.
Key points
From the paper's conclusion- This meta-analysis demonstrates that the sFlt-1/PIGF ratio exhibits superior diagnostic accuracy for preeclampsia, particularly during the second trimester.
Abstract
BACKGROUND: Preeclampsia, a life-threatening gestational complication for maternal-fetal health, necessitates prediction (across all trimesters) to improve clinical outcomes. Serum biomarkers, by revealing core pathological mechanisms such as angiogenic imbalance, have emerged as potential screening tools. However, the heterogeneity in their predictive efficacy and clinical utility requires evidence-based synthesis. OBJECTIVE: To comprehensively evaluate the predictive potential of seven categories of serum biomarkers and clarify their clinical application value. METHODS: Databases including PubMed, Embase, Cochrane Library, and Web of Science were searched from inception to January 20, 2026, to identify studies evaluating the diagnostic performance of serum biomarkers for preeclampsia. The methodological quality of included studies was assessed using the QUADAS-2 tool. Pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and area under the curve (AUC) were calculated using bivariate random-effects models and the hierarchical summary receiver operating characteristic (HSROC) model. RESULTS: A total of 22 studies (7,772 participants) were included. The sFlt-1/PIGF ratio demonstrated the highest diagnostic accuracy, with a pooled sensitivity of 85%, specificity of 83%, and AUC of 0.923. For individual biomarkers, sFlt-1 showed a sensitivity of 78% (95% CI: 74-82%) and specificity of 79% (95% CI: 75-83%) with an AUC of 0.881; PIGF showed a sensitivity of 74% (95% CI: 70-78%) and specificity of 76% (95% CI: 72-80%) with an AUC of 0.859. Endoglin and leptin exhibited moderate diagnostic performance (AUCs of 0.814 and 0.768, respectively) but were limited by high heterogeneity (I 2 > 75%). Activin A and inhibin A showed preliminary diagnostic potential (AUCs of 0.785 and 0.796, respectively), but these findings are based on only three studies each and require validation in larger prospective cohorts. Subgroup analysis revealed that diagnostic accuracy varied by gestational trimester, with the sFlt-1/PIGF ratio achieving the highest AUC (0.94) in the second trimester. Sensitivity analyses confirmed the robustness of the pooled estimates, and publication bias was assessed using Deeks' funnel plot. CONCLUSION: This meta-analysis demonstrates that the sFlt-1/PIGF ratio exhibits superior diagnostic accuracy for preeclampsia, particularly during the second trimester.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Emerging biomarkers and integrated models for preeclampsia prediction.American journal of clinical and experimental immunology · 2026
- sFlt-1/PlGF Ratio as a Central Biomarker for Preeclampsia and Perinatal Outcomes: A Multisystem Retrospective Cohort StudyJournal of Clinical Medicine · 2026
- Predictive Value of the Soluble fms-Like Tyrosine Kinase-1/Placental Growth Factor Ratio in Preeclampsia and Placenta Accreta Spectrum: A Prospective Observational Study.Cureus · 2026
- Present status of sFLT1 and PlGF as diagnostic and therapeutic targets for preeclampsiaThe Journal of Maternal-Fetal & Neonatal Medicine · 2026
- The Role of Angiogenetic Factors in PreeclampsiaInternational Journal of Molecular Sciences · 2025
- A-340 Clinical Implementation of sFlt-1/PlGF Biomarker Testing for Preeclampsia Risk Assessment at a Tertiary Care Centre: Summary of 5-year ExperienceClinical Chemistry · 2026