Frontiers in Mechanical Engineering

Parametric design selection and ambient experimental assessment of a beryllium-copper spiral flexure spring for long-life Stirling cryocooler compressors

Virendra Bhojwani, Suraj Bhoyar, Rakesh Sidheshware, Pralhad Tipole, Sunil Kulkarni

Key points

From the paper's conclusion
  • An ambient fatigue campaign reached 100,755,000 fully reversed cycles at ±5 mm and 50 Hz without detected crack initiation, exceeding the adopted 10 8 -cycle run-out criterion by 0.76%.

Abstract

Free-piston Stirling cryocoolers require flexure suspensions that combine low axial stiffness, high radial stiffness, modal separation, manufacturability and long cyclic endurance. This study reports a constrained, one-factor-at-a-time parametric screening procedure for a three-arm spiral flexure disc, followed by ambient experimental assessment of the selected design. Six candidate alloys (AISI 302, AISI 304, Be-Cu C17000, Be-Cu C17200 TH, Ti-6Al-4V and AMPCOLOY® 944) and five geometric variables (arm count, spiral-cut width, sweep angle, disc thickness and disc diameter) were screened using nonlinear static structural, modal and stress-life finite element analyses in ANSYS® Workbench, with photo-etch manufacturability treated as a hard feasibility constraint. The selected configuration was Be-Cu C17200 TH, three arms, 0.6 mm cut width, 0.7 mm disc thickness, 560° sweep, 69 mm diameter and ±5 mm design stroke. For the selected design, analytical, numerical and experimental axial stiffness values were 1495.00, 1451.45 and 1460.25 N/m, respectively; the three routes agreed within 3%, while FEA and experiment differed by 0.6%. Measured and predicted strain agreed within 3%–7% across the stroke. An ambient fatigue campaign reached 100,755,000 fully reversed cycles at ±5 mm and 50 Hz without detected crack initiation, exceeding the adopted 10 8 -cycle run-out criterion by 0.76%. This result is a run-out at one stress level rather than a statistical infinite-life demonstration. Cryogenic mechanical qualification, direct radial-stiffness measurement, and a formal global multi-objective optimisation remain outside the present evidence base.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Parametric design selection and ambient experimental assessment of a beryllium-copper spiral flexure spring for long-life Stirling cryocooler compressors — Science Skim