Frontiers in immunology

Magnetic enrichment-coupled flow cytometry for highly sensitive detection of persistent CAR-T cells in spiked and clinical peripheral blood samples.

Loubna Abdel Hadi, Gokul Thangamani, Samira Sheikh, Syed Mazher Hussain, Alvin Jon Ingel, Shahid Imtiaz Ahmed, Antonio Alfonso Bencomo Hernandez, Fatima Mohammed Al Kaabi,

Research and Development Department, Abu Dhabi Stem Cells Center, Abu Dhabi, United Arab Emirates.

Key points

From the paper's conclusion
  • The assay’s limit of detection and potential clinical utility were evaluated using CAR-T cell spike-in experiments in peripheral blood mononuclear cell (PBMC) backgrounds and clinical blood samples obtained from patients who received CD19-targeted CAR-T cell therapy.

Abstract

BACKGROUND: Long-term monitoring of chimeric antigen receptor T-cell (CAR-T) persistence is essential for assessing therapeutic efficacy, particularly when circulating CAR-T cell levels decline following infusion. Although quantitative real-time PCR (qPCR) provides highly sensitive detection of CAR transgenes, it lacks single-cell resolution, phenotypic characterization, and the ability to assess cell viability. METHODS: In this study, we adapted and validated an automated enrichment-mode on MACSQuant flow cytometry that integrates automated immunomagnetic enrichment with multiparametric flow cytometric analysis to enhance the sensitivity of detecting and quantifying rare CAR-T cell populations. The assay's limit of detection and potential clinical utility were evaluated using CAR-T cell spike-in experiments in peripheral blood mononuclear cell (PBMC) backgrounds and clinical blood samples obtained from patients who received CD19-targeted CAR-T cell therapy. Results were compared with a complementary qPCR assay for vector copy number (VCN) detection. RESULTS: The enrichment-based workflow enabled same-day detection of viable CAR-T cells by selectively enriching CAR-T cells while excluding non-target peripheral blood leukocytes, thereby substantially improving detection sensitivity at very low cell frequencies in post-infusion patient samples. Concordant CAR-T cell detection was observed between the enrichment-coupled flow cytometry workflow and qPCR. While qPCR served as an orthogonal approach for sensitive transgene detection, the enrichment-based flow cytometry workflow provided additional single-cell information, including viable CAR-T cell frequency and phenotypic characterization. CONCLUSION: By combining enhanced sensitivity with single-cell and functional resolution, this enrichment-coupled flow cytometry workflow complements qPCR-based genomic detection and may serve as a rapid, accurate, and clinically valuable tool for the longitudinal monitoring of CAR-T cell persistence in patients receiving CAR-T cell therapy.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers